Supraventricular pacemaker underdrive in the absence of sinus nodal influences in the conscious dog.
نویسندگان
چکیده
The ability to reduce and maintain heart rate by electrical stimulation (underdrive) was tested in three groups of chronically instrumented dogs: sinoatrial node intact, ectopic atrial pacemaker produced by injection of rapidly hardening latex into the sinoatrial nodal artery, and idioventricular pacemaker produced by injection of formalin into the atrioventricular node. In the conscious unsedated state, underdrive of sinoatrial or idioventricular pacemakers resulted in competition between driven and intrinsic foci. However, the cycle length of ectopic atrial pacemakers could be increased by 148.4 +/- 30.7 msec (P less than 0.001) and maintained at that value. Cessation of underdrive resulted in a period of pacemaker suppression similar to that produced following overdrive. Single premature stimuli produced marked cycle length prolongations in dogs with ectopic atrial foci. Total autonomic blockade had no significant effect on the production of underdrive. Thus, the results of the present experiments provide evidence for maintained capture of cardiac pacemakers at rates significantly below intrinsic control and indicate that underdrive varies as a function of pacemaker site. Underdrive may explain the failure of junctional escape in the presence of slower atrial rhythms.
منابع مشابه
Mechanism of Reentrant Arrhythmias and Its Relationship
12. Waldo AL, Kaiser GA: A study of ventricular arrhythmias associated with acute myocardial infarction in the canine heart. Circulation 47: 1222, 1973 13. Boineau JP, Cox JL: Slow ventricular activation in acute myocardial infarction. Circulation 48: 702, 1973 14. Scherlag BJ, El-Sherif N, Hope R, Lazzara R: Characterization and localization of ventricular arrhythmias resulting from myocardial...
متن کاملTreatment of paroxysmal nodal tachycardia by dual demand pacemaker in the coronary sinus.
A patient with refractory paroxysmal atrioventricular nodal re-entrant tachycardia had required direct current cardioversion to terminate attacks on 83 occasions. A dual demand pacemaker was implanted to sense and interrupt attacks of tachycardia automatically. The pacing electrode was positioned in the proximal coronary sinus near to the atrioventricular node; a site from which fixed rate unde...
متن کاملEffects of Nodal Position and Growth Regulators on In Vitro Growth of Dog Rose (Rosa canina)
Dog rose (Rosa canina) has been using as a rootstock for ornamental roses also it is one of the medicinal plants. It can be propagated under in vitro conditions. After removing chilling requirement of buds, axillary wood buds of dog rose were cut in three nodal positions (lower, middle and terminal) on the stem and then explants after decontamination, cultured on Murashige and Skoog medium (MS ...
متن کاملCoronary sinus rhythm induced by selective use of catecholamine in the in situ dog heart.
The selective administration of dopamine, norepinephrine, epinephrine and isoproterenol, into the coronary sinus region of the dog heart produced so-called coronary sinus rhythm, indicating the appearance of deep inverted P waves and frequently accompanied by an acceleration of pacemaker activity of the coronary sinus region. These effects of catecholamines were not influenced by atropine and t...
متن کاملOscillatory nature of AV nodal pacemaker activity.
The perfusion of the AV node artery in dog heart in vivo was performed. After destroying the sinoatrial node by selective injection of ethanol into the sinus node artery, the selective administration of catecholamines into the AV node artery induced acceleration of nodal rhythm. In the course of recovery, eminent oscillatory change in the AV nodal rhythm was regularly observed. This oscillatory...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation research
دوره 44 3 شماره
صفحات -
تاریخ انتشار 1979