Calibration of Oscilloscopes
نویسنده
چکیده
3 Performing the calibration 3.1 Fundamental principles of oscilloscopes 3.2 Description of the device under test 3.3 Calibration procedures 3.3.1 Calibration of the vertical deflection (amplitude calibration) 3.3.1.1 Traceability by DC 3.3.1.2 Traceability by AC 3.3.1.3 Traceability by pulse measurements 3.3.2 Calibration of the horizontal deflection (time base calibration)) 3.3.3 Calibration of the bandwidth 3.3.3.1 Measurement of voltage amplitudes (for bandwidth determination) 3.3.3.1.1 Traceability in the high impedance range (typically below 100 MHz) 3.3.3.1.2 Traceability in the 50 Ω line system 3.3.3.1.3 Influence of harmonic distortions 3.3.3.1.4 Flatness 3.3.4 Calibration of the rise time 3.3.5. Calibration of the trigger bandwidth and -sensitivity 3.3.5.1. Trigger bandwidth 3.3.5.1.1 Calibration procedure 3.3.5.2. Trigger sensitivity 3.3.5.2.1 Calibration procedure 3.3.6 Internal calibration signals 3.3.7 Cursor measurement 3.4 Determination of the uncertainties of measurement
منابع مشابه
Terminology for High - Speed Sampling - Oscilloscope Calibration Dylan
We discuss procedures for calibrating high-speed sampling oscilloscopes at the National Institute of Standards and Technology, and the terminology associated with those calibrations. The discussion clarifies not only the calibration procedures, but how to use the calibrations to perform traceable oscilloscope measurements.
متن کاملCalibration of a Magnetic Field Probe as a Diagnostic for Laser-Produced Plasma
Small, high speed B-dot probes were constructed and calibrated as instruments to detect the spontaneous magnetic field of laser-produced plasma, following established techniques. A network analyzer and oscilloscopes were used to diagnose the source of interference observed both in the calibration of the probes and in the laser-plasma measurements. Methods of reducing the interference were formu...
متن کاملBroadband Sampling Oscilloscope Characterization with the “nose-to-nose” Calibration Procedure: a Theoretical and Practical Analysis
In the past the “nose-to-nose” calibration procedure has been introduced as probably the most accurate method to determine the impulse response of broadband sampling oscilloscopes like the HP54124T. The method is based on the hypothesis “sampler kick-out equals oscilloscope impulse response”. This hypothesis was originally based on an intuitive approach and was later on verified experimentally ...
متن کاملCalibration of the Tektronix TDS 2014 Digital Oscilloscope
The Tektronix TDS 2014 is a four channel Digital Storage Oscilloscope (DSO) with 8-bit analogue to digital converter. This document reports on the calibration of the equipment for voltage measurements. A precise multimeter was used to calibrate the DSO. The calibration was performed by applying various DC voltages to the DSO and comparing the measurement results reported by the DSO and the mult...
متن کاملQuantifying the Maximum Phase-Distortion Error Introduced by Signal Samplers
Quantifying the errors introduced by signal sampler imperfections is of interest to people who are doing frequency domain measurements. The phase-distortion introduced by the sampler is hard to quantify and is usually neglected. In this article upper bounds for this phase-distortion error are derived which are based upon simple assumptions, namely that the sampler weighting function is strictly...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010