Effect of carotid endarterectomy on primary collateral blood flow in patients with severe carotid artery lesions.

نویسندگان

  • Jeroen Hendrikse
  • Dirk R Rutgers
  • Catharina J M Klijn
  • Bert C Eikelboom
  • Jeroen van der Grond
چکیده

BACKGROUND AND PURPOSE In patients with severe obstruction of the internal carotid artery (ICA), it is recognized that the preoperative failure to visualize collaterals of the circle of Willis increases the risk of hemispheric ischemia before, during, and after carotid endarterectomy (CEA). The purpose of the present study was to assess the effect of CEA on the anatomy and function of the circle of Willis. METHODS Time-of-flight and phase-contrast MR angiography were used to study changes in vessel diameter and collateral flow of the circle of Willis in 48 patients with 70% to 99% ICA stenosis before and after CEA. RESULTS In patients with unilateral ICA stenosis, all preoperative vessel diameters on both sides of the circle of Willis were larger than in control subjects. All demonstrated a significant diameter decrease to reach normal values after CEA. Furthermore, preoperative collateral flow patterns normalized after CEA (P=0.03). In patients with stenosis and contralateral ICA occlusion, CEA resulted in a significant increase in the prevalence of collateral flow via the anterior communicating artery (33% to 83%, P<0.01) and a significant increase in diameter of both A1 segments (P<0.05) in patients in whom collateral flow developed after CEA. CONCLUSIONS CEA reduces the caliber of compensatory collateral channels to normal levels by MR angiography measurements in the presence of severe unilateral stenosis; when the opposite side is occluded and the stenosis is removed ipsilaterally, a greater amount of compensatory collateral circulation can be measured on both the occluded side and the fully opened side.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Collateral cerebral vascular resistance in patients with significant carotid stenosis.

This study tests, the hypothesis that asymptomatic patients with hemodynamically significant internal carotid artery stenosis have a lower ipsilateral collateral cerebral vascular resistance and hence greater blood flow than their symptomatic cohorts. We measured internal carotid artery blood flow and cerebral perfusion pressures intraoperatively prior to and after carotid endarterectomy in 35 ...

متن کامل

Predicting the effect of carotid artery occlusion during carotid endarterectomy: comparing transcranial doppler measurements and cerebral angiography.

BACKGROUND AND PURPOSE We correlated the mean transcranial Doppler blood flow velocity (FVm) during carotid endarterectomy with the functional collateral pathway(s) documented by angiography. METHODS Three patient groups were established: group 1 was dependent on the anterior communicating artery, group 2 on the anterior communicating artery and ipsilateral posterior communicating artery, and...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Continuous-Wave Doppler in the Evaluation of Intracranial Collateral Circulation

Adequate intracranial collateral circulation reduces risk of stroke in carotid artery surgery. To evaluate their relative accuracies in assessing intracranial collateral blood flow, we prospectively compared transcranial Doppler and continuous-wave Doppler of the cervical carotid arteries combined with compression of the common carotid artery in 28 consecutive patients before carotid endarterec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 34 7  شماره 

صفحات  -

تاریخ انتشار 2003