Femoral deficiency reconstruction using a hydroxyapatite-coated locked modular stem. A series of 43 total hip revisions.
نویسندگان
چکیده
INTRODUCTION We report a continuous prospective series of patients operated on for total hip prosthesis femoral component loosening involving a bone defect. Reconstruction was performed using a hydroxyapatite-coated locked modular stem. The study's objective was to assess medium term clinical and X-ray results obtained with this original concept. MATERIALS AND METHODS The patients included received a REEF (DePuy) femoral implant for aseptic loosening or loosening associated with a periprosthetic fracture. Implantation was systematically accompanied by an extended trochanteric osteotomy (ETO). Patients were followed up prospectively by clinical and X-ray examination. Their loosening was graded at inclusion according to Vives' classification as revised by SOFCOT in 1999. Analysis focused on actuarial implant survivorship, dislocation and the bone/implant interface. RESULTS Forty-three hips were included: mean follow-up was 58.2 months (12-92) and mean age at surgery was 72.4 years (37-94). The main indications were severe bone loss rated grade III (n=15) or IV (n=16) according to the SOFCOT classification. There was one long-term failure, involving implant fracture secondary to nonunion of the femoral shaft. Mean Postel and Merle d'Aubigné (PMA) clinical assessment score increased from six preoperatively to 14.5 at end of follow-up. X-ray analysis found no stem migration by end of follow-up. There was consistent consolidation of the ETO around the stem, except in one case of stem fracture which evolved into tight nonunion. In terms of metaphyseal integration, five patients showed radiolucency without evolution over follow-up, and eight had severe calcar cortical atrophy at end of follow-up. Mean 5-year actuarial survivorship was 97.7+/-2.3%, with a 2% incidence of dislocation. DISCUSSION The complications rate was low, and results were comparable with those reported in the literature. The study confirmed the interest of the extended trochanteric osteotomy exposure and the effectiveness of the hydroxyapatite-coated interlocked modular stem concept in the treatment of hip prosthesis loosening with femoral bone loss (involving or not the cortex). On analysis, the one case of failure does not prescribe the surgical technique employed. Implant osseointegration was difficult to analyze. The extent of the surgical approach and of its corresponding sequels, combined with the complexity of adjusting the implant, however, restrict this surgical option indications to level III and IV cases of femoral loosening.
منابع مشابه
Outcomes of long tapered hydroxyapatite-coated stems in revision total hip arthroplasty.
The purpose of this study was to evaluate the outcome of femoral component revisions using a long tapered HA coated femoral revision stem. Between 2001 and 2008, 55 femoral component revisions were performed using this stem. Forty-one patients were available for follow up evaluation at average of 59 months. The clinical results were evaluated using the HHS and serial radiographs were evaluated ...
متن کاملThe Freeman femoral component with hydroxyapatite coating and retention of the neck: an update with a minimum follow-up of 17 years.
The outcome at ten years of 100 Freeman hip stems (Finsbury Orthopaedics, Leatherhead, United Kingdom) retaining the neck with a proximal hydroxyapatite coating in a series of 52 men (six bilateral) and 40 women (two bilateral), has been described previously. None required revision for aseptic loosening. We have extended the follow-up to 20 years with a minimum of 17 years. The mean age of the ...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملHydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival.
The purpose of this study was to evaluate the long-term clinical outcomes of primary total hip arthroplasty using an uncemented, hydroxyapatite-coated implant. We followed a consecutive series of 164 patients, who underwent total hip arthroplasty with the Furlong fully-hydroxyapatite coated implant over a mean time period of 12.8 years. Clinical and radiological analyses were performed. Roentge...
متن کاملThe Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem
PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopaedics & traumatology, surgery & research : OTSR
دوره 95 2 شماره
صفحات -
تاریخ انتشار 2009