The Effect of Pattern Materials on the Marginal Gap of Metal Copings Fabricated On Titanium Implant Abutments
نویسندگان
چکیده
Aims: This study was aimed to compare the effect of three different pattern materials on the vertical marginal discrepancy of Nickel-Chromium copings fabricated on titanium implant abutments. Methods: A titanium implant abutment was used to receive 30 Nickel-Chromium copings. The copings were constructed using pattern wax (group 1), acrylic pattern resin (group 2), and lightcured pattern resin (group 3). The marginal gap of the Nickel-Chromium copings was measured at 4 points on the abutmentimplant assembly by using a digital microscope. One-way ANOVA and post hoc tests were adopted for statistical analysis (α=0.05). Results: The mean marginal gap values of Nickel-Chromium copings fabricated from pattern wax, acrylic pattern resin, and lightcured pattern resin were 34.00, 31.78 and 25.87 μm, respectively. There was a statistically significant difference between groups 1 and 3 (p=0.02), whilst the difference between groups 2 and 3 and between groups 1 and 2 was not statistically significant (p>0.05). Conclusions: The marginal gaps of the copings, fabricated from tested pattern materials, were within the clinically acceptable range. Nevertheless, light-cure pattern resin had a better vertical marginal fit than acrylic pattern resin and pattern wax.
منابع مشابه
The evaluation and comparison of marginal adaptation in metal ceramic and all ceramic restorations fabricated by two methods: CAD/CAM and conventional
Introduction: Marginal fit is a key factor for long term clinical success through any dental restorations. Poor marginal adaptation causes cement dissolution. This can lead to dental caries, gingival irritation, periodontal diseases, and finally treatment failure. The aim of this study was measurement and comparison of marginal gap quantities in metal ceramic and all ceramic dental restorations...
متن کاملComparative evaluation of bonding strength of computer aided machined ceramic, pressable ceramic, and milled metal implant abutment copings and effect of surface conditioning on bonding strength: An in vitro study
BACKGROUND/PURPOSE The aim of this study was to compare the shear bond strength of computer aided design/computer aided machined ceramic (CAD/CAM), pressable ceramic, and milled metal implant copings on abutment and the effect of surface conditioning on bonding strength. MATERIALS AND METHODS A total of 90 test samples were fabricated on three titanium abutments. Among 90 test samples, 30 cop...
متن کاملEffect of Three Types of Temporary Luting Cements and Abutment Surface Sandblasting on Retentive Strength of Implant-Supported Fixed Prostheses
Background and Aim: Achieving appropriate retention and easy retrieva bility at the same time is challenging in implant-supported fixed par tial dentures (FPDs). Researchers have always been in search of a temporary cement to improve the retentive strength. The aim of this in vitro study was to evaluate the effect of three different temporary ce ments and sandblasting of the abutment surface on...
متن کاملبررسی تطابق کوپینگهای ساخته شده به دنبال استفاده از اسکنر داخل دهانی در دو ختم تراش زیر و حد لثه در سطوح مختلف دندانی
Background and Aims: Despite the increasing application of intra-oral scanners, the effect of finish line position on gingival margins adaptation is still discussed. The purpose of this clinical study was to evaluate the fitness of cobalt-chromium copings obtained from intraoral scanning in two depth of finish lines. Materials and Methods: Thirty teeth prepared for single premolar metal-cerami...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کامل