Access of Hydrogen-Radicals to the Peptide-Backbone as a Measure for Estimating the Flexibility of Proteins Using Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

نویسندگان

  • Mitsuo Takayama
  • Keishiro Nagoshi
  • Ryunosuke Iimuro
  • Kazuma Inatomi
چکیده

A factor for estimating the flexibility of proteins is described that uses a cleavage method of "in-source decay (ISD)" coupled with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). The MALDI-ISD spectra of bovine serum albumin (BSA), myoglobin and thioredoxin show discontinuous intense ion peaks originating from one-side preferential cleavage at the N-Cα bond of Xxx-Asp, Xxx-Asn, Xxx-Cys and Gly-Xxx residues. Consistent with these observations, Asp, Asn and Gly residues are also identified by other flexibility measures such as B-factor, turn preference, protection and fluorescence decay factors, while Asp, Asn, Cys and Gly residues are identified by turn preference factor based on X-ray crystallography. The results suggest that protein molecules embedded in/on MALDI matrix crystals partly maintain α-helix and that the reason some of the residues are more susceptible to ISD (Asp, Asn, Cys and Gly) and others less so (Ile and Val) is because of accessibility of the peptide backbone to hydrogen-radicals from matrix molecules. The hydrogen-radical accessibility in MALDI-ISD could therefore be adopted as a factor for measuring protein flexibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fragmentation processes of hydrogen-deficient peptide radicals in matrix-assisted laser desorption/ionization in-source decay mass spectrometry.

The mechanism of in-source decay (ISD) in matrix-assisted laser desorption/ionization (MALDI) has been described. The MALDI-ISD with an oxidizing matrix is initiated by hydrogen abstraction from peptides to matrix molecules, leading to hydrogen-deficient peptide radicals. Subsequently, the C(α)-C and C(α)-H bonds are cleaved, forming the a•/x fragment pair and [M-2H], respectively. Those reacti...

متن کامل

Specific recognition of DNA bulge structure by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

This study reports a novel approach utilizing an octahedral CoII(HAPP)(TFA)2 reagent in the presence of H2O2 with analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to serve as an efficient probe for bulged DNA structures. Elucidation of DNA bulge-specific recognition pathways and cleavage mechanisms is demonstrated by characterization of bulg...

متن کامل

Comparative proteomics analysis of a novel g-radiation-resistant bacterium wild-type Bacillus megaterium strain WHO DQ973298 recovering from 5 KGy g-irradiation

In order to examine radiation-induced proteins in an extremely radio-resistant bacterium, it became possibleto perform comparative proteomic analysis on radio-resistance Bacillus megaterium WHO as a wildtypestrain for the first time. Variation in cellular proteins profiles of the Bacillus megaterium WHO after 5KGy γ-irradiation were analyzed by two-dimensional poly acryl amide...

متن کامل

Products of Cu(II)-catalyzed oxidation in the presence of hydrogen peroxide of the 1-10, 1-16 fragments of human and mouse beta-amyloid peptide.

The interactions of proteins with reactive oxygen species (ROS) may result in covalent modifications of amino acid residues in proteins, formation of protein-protein cross-linkages, and oxidation of the protein backbone resulting in protein fragmentation. In an attempt to elucidate the products of the metal-catalyzed oxidation of the human (H) and mouse (M) (1-10H), (1-10M), (1-16H) and (1-16M)...

متن کامل

MALDI-MS: a Rapid and Reliable Method for Drug-to-Antibody Ratio Determination of Antibody-Drug Conjugates

Background: It is believed that the loading value of anticancer drug conjugated to the monoclonal antibody, called drug-to-antibody ratio (DAR), is the main quality feature of antibody-drug conjugates. Methods: In this study, matrix assisted laser desorption/ionization mass spectrometry was used to determine the average molecular weight of trastuzumab and its three conjugated forms. The differe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014