Catheter semiconductor radiation detector for continuous measurement of cardiac output.
نویسندگان
چکیده
CATHETER SEMICONDUCTOR RADIATION DETECTOR FOR CONTINUOUS MEASUREMENT OF CARDIAC OUTPUT Hideo Ueda, Yashito Sasaki, Masahiro ho, Shigekoto Kaihara, Kikuo Machida, Iwao Ito, Sei-ichi Takayanagi, Tetsuji Kabayashi and Tohru Sugita 713 A METHOD FOR CHROMATOGRAPHIC SEPARATION OF IODO COMPOUNDS WITH A COMPUTER PROGRAM FOR DATA ANALYSIS R. E. Goldsmith, R. Kioth, H. E. Berry, J. Rauh, J. Landwehr and G. Bahr 722 HIGH-RESOLUTION GAMMA-RAY SPECTROMETRY IN THE DETERMINATION OF TRACE ELEMENTS IN HUMAN FINGERNAILS A. A. Petushkov, D. M. Linekin, J. F. Balcius and G. L. Brownell 730 THE QUESTION OF RADIATION EXPOSURE TO THE HAND FROM HANDLING e9mTc C. M. Neil 732 DETERMINATION OF RENAL PLASMA FLOW BY A SINGLE INJECTION OF †̃31I-ORTHOIODOHIPPURATE AND TWO BLOOD SAMPLES: EVALUATION OF THE PRECISION OF THIS METHOD Barna Vityéand Etienne LeBel 735
منابع مشابه
Measurement of stereotactic beam data of 9 MV X-rays using diode detector
Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...
متن کاملFailure of continuous cardiac output measurement using the PiCCO Device during induced hypothermia: a case report.
Continuous cardiac output measurement using pulse contour analysis is a technique gaining widespread acceptance in intensive care units. We report a case where a pulse contour analysis computer (PiCCO, Pulsion Medical Systems, Munich, Germany) failed to calibrate in a patient who was undergoing induced hypothermia for anoxic brain injury. Despite several attempts to calibrate, using increased c...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملCARDIOVASCULAR Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
Editor’s key points † Previously, continuous cardiac output (CO) measurement techniques required the insertion of a pulmonary artery catheter. † The PiCCO and VolumeView systems use arterial pulse contour analysis for continuous CO measurement. † Both require calibration with transpulmonary thermodilution (TPTD) measurements using a central venous catheter. † The current study compared the perf...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 10 12 شماره
صفحات -
تاریخ انتشار 1969