Quantitative Analysis of Chloramphenicol in Royal Jelly by Column-switching LC-MS/MS Using a Pretreatment Column with a Higher-pressure Capability.

نویسندگان

  • Shin-ichi Kawano
  • Yoshihiro Hayakawa
  • Yuki Hashi
  • Jin-Ming Lin
چکیده

An on-line pretreatment liquid chromatography-tandem mass spectrometry (LC-MS/MS) system was developed for the analysis of chloramphenicol (CAP) in royal jelly. A novel methylcellulose-immobilized restricted access media column with a higher-pressure capability of 60 MPa (MC-ODS HP) was developed for the effective removal of proteins and other compounds in the sample matrix. CAP in a sample solution was extracted in 2 min by the column-switching LC-MS/MS system. The system provides a minimum sample pretreatment along with highly sensitive and reproducible analysis. As a result, the limit of quantitation of CAP was 10 pg/mL (= 0.1 μg/kg royal jelly) and the linear dynamic range was between 10 and 10000 pg/mL (correlation coefficient greater than 0.999). The proposed method meets the requirements of regulations in EU (0.3 μg/kg). The inter-day precision and accuracy of CAP at 100 pg/mL over 3 days were 4.5 and 95.4%, respectively. Compared with the conventional method with a pressure of below 25 MPa, the peak separation in the MRM chromatogram was improved by using smaller particles (1.6 μm) for the analytical ODS column. The LC-MS/MS system with an MC-ODS HP expanded the applicability of the automated pretreatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Liquid Chromatography− and Capillary Electrophoresis−Mass Spectrometry in Glucuronide Analysis by

Phase II metabolites, or conjugates, are highly polar, non-volatile and thermolabile compounds that need to be analysed in biological matrices such as urine, bile and plasma. Liquid chromatography (LC) and capillary electrophoresis (CE) are proven techniques for the analysis of compounds of this kind, but the standard detectors in LC and CE lack sensitivity and especially specificity. Coupling ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2015