Results with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty.

نویسندگان

  • Alessandro Bistolfi
  • Sebastien Lustig
  • Federica Rosso
  • Paola Dalmasso
  • Maurizio Crova
  • Giuseppe Massazza
چکیده

Rotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthroplasties Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) implanted for knee osteoarthritis. The Hospital for Special Surgery Knee Score and the Knee Society Score were used for the clinical and radiographic evaluation. Log-rank or Wilcoxon tests were used to test the statistical significances, and the Kaplan-Maier method was used to calculate the implant survival probability. After a medium follow-up of approximately 174 months, the clinical scores showed a statistically significant improvement from the pre- to postoperative period. The complication rate was high, and the cumulative implants survival rate was 88.7% at 1 year, 85.9% at 5 years, 79.8% at 10 years, and 75.8% at 15 years. The Endo-Modell rotating hinge implants demonstrated no significant risk of aseptic loosening, and the hinge was not a primary cause of failure. However, the overall failure rate was higher than that of unhinged implants; therefore, this prosthesis is recommended for cases of instability and revision rather than primary knee arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endo-Modell rotating-hinge total knee for revision total knee arthroplasty.

The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge pr...

متن کامل

Better Outcomes in Severe and Morbid Obese Patients (BMI > 35 kg/m2) in Primary Endo-Model Rotating-Hinge Total Knee Arthroplasty

The Endo-Model rotating-hinge prosthesis is preferably indicated as a primary implant in patients with advanced axial deviation of the lower limbs or unstable knees with severe bone defects. Outcomes were studied in 111 knees, operated in a three-year period; the mean followup was 28 months. Joint balance enhancement and limbs mechanical axis correction were achieved after surgery. There were 6...

متن کامل

Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision

The aim of the study was to evaluate the mid-term clinical results and survivorship of a rotating-hinge knee prosthesis (LINK® Endo-Model) in difficult primary and complex revision situations. Results after primary implantation were compared with those of revision procedures. Forty-nine prostheses in 45 patients were reviewed clinically during follow up. Twenty-one of these were implanted in pr...

متن کامل

Early Results of a New Rotating Hinge Knee Implant

BACKGROUND Indication for rotating hinge (RH) total knee arthroplasty (TKA) includes primary and revision cases, with contradictory results. The aim of this study was to report prospective early results of a new modular rotating hinge TKA (EnduRo). For this implant several new design features and a new bearing material (carbon-fiber reinforced poly-ether-ether-ketone) have been developed. Furth...

متن کامل

In vivo testing of knee stability after rotating-hinge total knee arthroplasty: a comparison of 2 knee systems.

Rotating-hinge knee prostheses are used for reconstruction in cases of severe articular compromise and major bone loss. Biomechanical studies revealed that rotating-hinge designs with long and cylindrical pegs are more stable than devices with short and more tapered ones. Twenty-five patients underwent clinical examination using ultrasound, radiographs, and 3 different rating systems to examine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2013