The characterization and transmission of scattered radiation resulting from x-ray beams filtered with zero to 0.99 mm copper.
نویسندگان
چکیده
The specification of shielding for fluoroscopic facilities in the UK is based on the determination of scatter incident on a barrier using a simple formula linking kerma area product and scatter kerma. Over the last few years there has been a move to incorporate additional copper filtration in equipment used for high dose fluoroscopic and interventional examinations, and the existing formula does not take this into account. The spectral and transmission characteristics of the scattered radiation resulting from a primary x-ray beam filtered with additional copper are not known. In this study, the relationship between primary and scattered radiation in these beams has been investigated as have their transmission characteristics. The scatter kerma area product from filtered beams is shown to be greater than that from conventional x-rays and a simple numerical correction linking the two has been derived. The implications for shielding calculations have been assessed and the impact of the correction on calculated barrier thickness has been shown to be relatively small. The broad beam transmission characteristics of the radiation scattered from the filtered beams have been simulated using Monte Carlo methods and found to be adequately described by the standard transmission equation using conventional coefficients.
منابع مشابه
Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملInvestigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray
Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...
متن کاملA proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins
Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...
متن کاملCharacterization of Copper-Manganese Oxide Catalysts and Their Precursors: Effect of Precipitate Aging upon the Structure and Morphology of Precursors and Catalysts
Copper-manganese oxide catalysts are prepared with an atomic ratio of Cu/Mn=2/1 using a coprecipitation procedure under air atmosphere. The time of aging, i.e., the time that precipitate remains in contact with the precipitating medium, has been varied from 0 (for unaged precursor) to 300 minutes and the effect of precipitate aging time in each atmosphere upon the structure and morphology of di...
متن کاملA Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.
Existing data used to calculate the barrier transmission of scattered radiation from computed tomography (CT) are based on primary beam CT energy spectra. This study uses the EGSnrc Monte Carlo system and Epp user code to determine the energy spectra of CT scatter from four different primary CT beams passing through an ICRP 110 male reference phantom. Each scatter spectrum was used as a broad-b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiological protection : official journal of the Society for Radiological Protection
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2012