Electromechanical coupling I. Introduction.
نویسنده
چکیده
In skeletal muscle fibres contraction is initiated by the action potential which travels inward along the transverse tubular system and causes in some way the release of Ca from the terminal cisternae of the sarcoplasmic reticulum (SR). Ca-release is probably controlled by a potential-sensor (intram em brane charge movement) in the wall of the T-system which in a triad is about 10 20 nm apart from the mem brane of cisternae. Little is known about the (chemi cal?) processes which ultimately bridge this gap and which might be associated with the so-called feet or pillars observed between the two systems. Ca ions which enter the fibre during the course of an action potential are not a prerequisite for contraction acti vation but modify the mechanical response by im proving the coupling efficiency and retarding inhi bition of Ca-release. During a tetanus or a depolari zation the increase in internal Ca2+ as observed with the aequorin-method shows a complicated time course with usually two peaks. This suggests that activation occurs in two steps. The latter might prob ably be related to the phenomenon called Ca induc ed regenerative Ca-release. Considering some structural similarities between skeletal and heart muscle cells it appears that EC coupling follows the same principle in both muscle types and that different responses upon activation are rather due to modifications of the same principle and not an expression of completely different pro cesses in EC coupling. The situation may be dif ferent in other muscle types.
منابع مشابه
The Effect of Bronchial Asthma on Interatrial Electromechanical Delay Coupling Obtained Using Tissue Doppler Imaging
Background: Asthma is a predisposing factor for the development of atrial fibrillation. Asthma disturbs the electrophysiology in the right and left atrium. The aim of this study was to evaluate atrial electromechanical delay by coupling obtained from tissue Doppler imaging (TDI) in children. Methods: A cross-sectional study was conducted on 50 patients with Bronchial Asthma, compared with 50 hea...
متن کاملMeasuring and Modeling Radiation Loss in Superconducting Microwave Re-entrant Cavities
This thesis describes the potential use of re-entrant microwave resonant three-dimensional cavities as low-loss electrical component in strongly coupled electromechanical systems. In particular , I have investigated radiative processes as a loss mechanism of a re-entrant cavity in a geometry similar to those used in electromechanical experiments undertaken by the Lehnert lab. First, I present t...
متن کاملIn silico investigation of the short QT syndrome, using human ventricle models incorporating electromechanical coupling
INTRODUCTION Genetic forms of the Short QT Syndrome (SQTS) arise due to cardiac ion channel mutations leading to accelerated ventricular repolarization, arrhythmias and sudden cardiac death. Results from experimental and simulation studies suggest that changes to refractoriness and tissue vulnerability produce a substrate favorable to re-entry. Potential electromechanical consequences of the SQ...
متن کاملElectrets in soft materials: nonlinearity, size effects, and giant electromechanical coupling.
Development of soft electromechanical materials is critical for several tantalizing applications such as soft robots and stretchable electronics, among others. Soft nonpiezoelectric materials can be coaxed to behave like piezoelectrics by merely embedding charges and dipoles in their interior and assuring some elastic heterogeneity. Such so-called electret materials have been experimentally sho...
متن کاملEnhanced electromechanical coupling of a nanomechanical resonator to coupled superconducting cavities.
We investigate the electromechanical coupling between a nanomechanical resonator and two parametrically coupled superconducting coplanar waveguide cavities that are driven by a two-mode squeezed microwave source. We show that, with the selective coupling of the resonator to the cavity Bogoliubov modes, the radiation-pressure type coupling can be greatly enhanced by several orders of magnitude, ...
متن کاملAtrial electromechanical coupling intervals in pregnant subjects
OBJECTIVE The aim of this study was to evaluate atrial conduction abnormalities obtained by tissue Doppler imaging (TDI) and electrocardiogram analysis in pregnant subjects. METHODS A total of 30 pregnant subjects (28 ± 4 years) and 30 controls (28 ± 3 years) were included. Systolic and diastolic left ventricular (LV) function was measured using conventional echocardiography and TDI. Inter-at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Zeitschrift fur Naturforschung. Section C, Biosciences
دوره 37 7-8 شماره
صفحات -
تاریخ انتشار 1982