Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation.

نویسندگان

  • Yiping P Du
  • Manish Dalwani
  • Korey Wylie
  • Eric Claus
  • Jason R Tregellas
چکیده

Susceptibility-induced magnetic field gradients (SFGs) can result in severe signal loss in the orbitofrontal cortex (OFC) in gradient-echo-based functional MRI (fMRI) studies. Although conventional z-shim techniques can effectively recover the MRI signal in this region, the substantial penalty in imaging time hampers their use in routine fMRI studies. A modified z-shim technique with high imaging efficiency is presented in this study. In this technique, z-shim compensations are applied only to a selective volume where the susceptibility artifact is severe. The results of an fMRI study (N=6) demonstrate the feasibility of detecting the OFC activation with z-shim in whole-brain fMRI studies at a temporal resolution of 2 s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Volume-Selective z-Shim and EPI with an fMRI Memory Task

shimming > epi; right: epi > z-shimming. P < 0.05 uncorrected. Fig. 2. Activation map from 6 subjects using z-shimming (left) and normal EPI (right). P < 0.01 uncorrected. Fig. 1. schematic drawing of the volume selective z-shimming slices. Solid lines: actual slices for imaging; solid red lines: slices to apply z-shim; dashed red lines: virtual slices during slice positioning, the actual slice...

متن کامل

Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.

The signal loss susceptibility artifact is a major limitation in gradient-echo MRI applications. Various methods, including z-shim techniques and multidimensional tailored radio frequency (RF) pulses, have been proposed to mitigate the through-plane signal loss artifact, which is dominant in axial slices above the sinus region. Unfortunately, z-shim techniques require multiple steps and multidi...

متن کامل

Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T.

Most functional magnetic resonance imaging (fMRI) studies record the blood oxygen level-dependent (BOLD) signal using fast gradient-echo echo-planar imaging (GE EPI). However, GE EPI can suffer from substantial signal dropout caused by inhomogeneities in the static magnetic field. These field inhomogeneities occur near air/tissue interfaces, because they are generated by variations in magnetic ...

متن کامل

3D z-shim method for reduction of susceptibility effects in BOLD fMRI.

Susceptibility-induced magnetic field gradients (SFGs) perpendicular to the slice plane often result in signal dropout in blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) experiments. Two-dimensional (2D) z-shim methods reduce these effects by acquiring multiple images with different slice refocusing gradient areas. In this work a 3D z-shim method is introdu...

متن کامل

Improved susceptibility weighted imaging method using multi-echo acquisition.

PURPOSE To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 57 2  شماره 

صفحات  -