Response characteristics of a dual transcutaneous oxygen/carbon dioxide monitoring system.
نویسندگان
چکیده
We tested the response characteristics of a dual transcutaneous (tc) PO2/PCO2 monitoring system in healthy subjects who breathed various gas mixtures, and we compared steady-state tc readings to simultaneous arterial blood gas analysis in 20 stable respiratory outpatients. The electrodes were simple to apply, required very little skin preparation, and had trivial signal drift. In healthy subjects, tcPCO2 lag time during CO2 rebreathing was 16.8 seconds, with a 90 percent response time of 77.9 seconds after CO2 breathing was discontinued. The 90 percent response times of the O2 electrode when subjects breathed a hypoxic mixture was 257 seconds after a lag of 31 seconds. When inhaled gas mixtures were changed from hypoxia to room air, the lag time was shorter (12.5 seconds), but 90 percent response time exceeded 5 minutes. In stable patients with respiratory disease, tcPCO2 and tcPO2 were linearly related to PaCO2 (range, 19 to 53 mm Hg) and PaO2 (range, 45 to 99 mm Hg), respectively (tcPCO2 = 1.4 PaCO2-9.44, with r = 0.90 and SEE = 5.35 mm Hg; tcPO2 = 0.56 PaO2 + 20.4, with r = 0.53 and SEE = 11.7 mm Hg). We conclude that the response of the dual transcutaneous monitoring system is more rapid for the CO2 than the O2 electrode and may be rapid enough to be useful in some clinical settings; however, the O2 system fails to offer the response characteristics and accuracy that would allow it to be substituted for arterial gas tensions in unstable clinical situations.
منابع مشابه
Continuous transcutaneous monitoring of peripheral oxygen and carbon dioxide during infant cardiac surgery
Close monitoring of the balance between oxygen demand and supply is of great importance during cardiac cardiopulmonary bypass (CPB) surgery. This study was to compare conventional intermittent venous blood gas monitoring with continuous transcutaneous oxygen and carbon dioxide monitoring in infant patients undergoing cardiac surgery with CPB. According to paired data from 29 infant patients und...
متن کاملNoninvasive monitoring of oxygen and carbon dioxide.
New technologies for the noninvasive assessment of oxygen and carbon dioxide are transforming clinical practice. Transcutaneous monitoring of PO2 (PtcO2) and PCO2 (PtCO2) provides an approximation of PaO2 and PaCO2 values in hemodynamically normal individuals, but both PtcO2 and PtcCO2 diverge from the corresponding arterial values when cardiac output is reduced, even in the absence of hypotens...
متن کاملPerformance of transcutaneous PO2 and PCO2 dual electrodes in adults.
Three commercially-available combined PO2-PCO2 electrodes were assessed in vitro, and in adults breathing air, hypoxic and hypercapnic mixtures, for speed of response, correlation with end-tidal gas tensions and drift. Differences in the 90% response time of the individual electrodes were more marked in vitro than in vivo. Changes in end-tidal gas tensions were reflected by proportionate change...
متن کاملMonitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea.
OBJECTIVES The purpose of the study was to evaluate a novel, combined sensor for transcutaneous monitoring of arterial oxygen saturation and carbon dioxide tension. DESIGN The new monitoring technique was compared to established reference methods. SETTING ICU and sleep laboratory of a university hospital. PATIENTS Eighteen critically ill adult patients with acute respiratory failure or he...
متن کاملHypoxaemia in wheezy infants after bronchodilator
The response of the bronchi to nebulised salbutamol was measured in five recurrently wheezy infants. Changes in oxygenation (measured by pulse oximeter and transcutaneous P02 electrodes) and carbon dioxide (measured by transcutaneous PCO2 electrode) were recorded at the same time. Neither nebulised saline nor salbutamol caused any changes in the measurements of airway function. A significant dr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 99 5 شماره
صفحات -
تاریخ انتشار 1991