Speech Intelligibility in Various Noise Conditions with the Nucleus® 5 CP810 Sound Processor
نویسندگان
چکیده
The Nucleus(®) 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of -8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.
منابع مشابه
The effect of redesign workstation on Speech Interference Level (SIL) among bank tellers
Abstract Background: There is always an interaction between man and his environment that can be the cause of physical, physiological and psychological stress on people and also cause discomfort, annoyance, and have direct and indirect effects on their performance and productivity, health and safety. People in their workplace are exposed to many factors related to work activities and environmen...
متن کاملConversion of adult Nucleus® 5 cochlear implant users to the Nucleus® 6 system.
OBJECTIVES Cochlear's new sound processor system (Nucleus(®) 6) features a new noise reduction algorithm called SNR-NR (signal-to-noise ratio), and an environmental classifier called SCAN, which activates the appropriate sound coding algorithms for a given listening environment. In addition, the sound processors (CP910 and CP920) have a data logging feature with data visually summarized using c...
متن کاملSpeech Intelligibility in Adverse Conditions in Recorded Virtual Auditory Environments
The purpose of this investigation was to examine the effects of presentation mode on speech intelligibility in adverse listening conditions as signal-to-noise ratio was systematically varied in anechoic and reverberant environments. Speech intelligibility scores were obtained from 21 normally hearing listeners using a nonsense syllable test. The syllables were recorded in three environments (mo...
متن کاملModulation-Based Digital Noise Reduction for Application to Hearing Protectors to Reduce Noise and Maintain Intelligibility
OBJECTIVE The objective of this study was to test the effects of modulation-based digital noise reduction (MB-DNR) on noise levels, speech intelligibility, and listening preference in four real-world noises. BACKGROUND A significant challenge in hearing protection device (HPD) design is to reduce ambient noise levels while maintaining users' ability to understand speech. MB-DNR technology, cu...
متن کاملTransient Noise Reduction in Cochlear Implant Users: a Multi-Band Approach
A previously-tested transient noise reduction (TNR) algorithm for cochlear implant (CI) users was modified to detect and attenuate transients independently across multiple frequency-bands. Since speech and transient noise are often spectrally distinct, we hypothesized that benefits in speech intelligibility can be achieved over the earlier single-band design. Fifteen experienced CI users (49 to...
متن کامل