Ash Fouling Monitoring and Key Variables Analysis for Coal Fired Power Plant Boiler

نویسندگان

  • Yuanhao SHI
  • Jingcheng WANG
چکیده

Ash deposition on heat transfer surfaces is still a significant problem in coal-fired power plant utility boilers. The effective ways to deal with this problem are accurate on-line monitoring of ash fouling and soot-blowing. In this paper, an online ash fouling monitoring model based on dynamic mass and energy balance method is developed and key variables analysis technique is introduced to study the internal behavior of soot-blowing system. In this process, artificial neural networks (ANN) are used to optimize the boiler soot-blowing model and mean impact values method is utilized to determine a set of key variables. The validity of the models has been illustrated in a real case-study boiler, a 300MW Chinese power station. The results on same real plant data show that both models have good prediction accuracy, while the ANN model II has less input parameters. This work will be the basis of a future development in order to control and optimize the soot-blowing of the coal-fired power plant utility boilers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Slag Occurrence in a Lignite-Fired Utility Boiler

Lignite from Mae Moh mine is the largest source of solid fuel for electricity generation in Thailand. It is used in pulverized coal-fired boilers of a 2400 MW thermal power plant. Its high CaO content in ash is a major concern that can affect severe slagging. In this paper, potential of slag occurrence in the power plant was investigated by numerical simulation. The FactSage thermochemical pack...

متن کامل

Mining Temporal Data: A Coal-Fired Boiler Case Study

This paper presents an approach to control pluggage of a coal-fired boiler. The proposed approach involves statistics, data partitioning, parameter reduction, and data mining. The proposed approach was tested on a 750 MW commercial coal-fired boiler affected with a fouling problem that leads to boiler pluggage that causes unscheduled shutdowns. The rare-event detection approach presented in the...

متن کامل

Cost analysis of a coal-fired power plant using the NPV method

The present study investigates the impact of various factors affecting coal-fired power plant economics of 210 MW subcritical unit situated in north India for electricity generation. In this paper, the cost data of various units of thermal power plant in terms of power output capacity have been fitted using power law with the help of the data collected from a literature search. To have a realis...

متن کامل

Computer modeling of a convective steam superheater

Superheater is for generating superheated steam from the saturated steam from the evaporator outlet. In the case of pulverized coal fired boiler, a relatively small amount of ash causes problems with ash fouling on the heating surfaces, including the superheaters. In the convection pass of the boiler, the flue gas temperature is lower and ash deposits can be loose or sintered. Ash fouling not o...

متن کامل

Arsenic leachability and speciation in fly ashes from coal fired power plants

To determine dominant factors on arsenic leaching from the coal fly ash, arsenic leaching test under a constant pH was performed. Twelve fly ash samples were collected from two coal fired power plants (600 MWe) having different boiler types. Arsenic in the raw coal was almost all associated with the fly ash in both power plants; however arsenic leaching fraction was strongly differed in boiler ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013