Influence of the femoral head size on early postoperative gait restoration after total hip arthroplasty.

نویسندگان

  • Yi-xin Zhou
  • Sheng-jie Guo
  • Qing Liu
  • Jing Tang
  • Yu-jun Li
چکیده

BACKGROUND We investigated the effects of using large-diameter femoral heads in total hip prostheses on early postoperative gait restoration in patients undergoing total hip arthroplasty (THA). METHODS We collected data for 19 primary THAs using 28-mm metal-on-polyethylene heads (conventional group) and for 12 THAs (BHR group) using metal-on-metal femoral heads with an average size of 45 mm (range, 40 - 49 mm). All patients had unilateral femoral head avascular necrosis. All patients underwent Harris Hip Scores evaluation and gait analysis with the IDEEA device at the same 3 time points which were before surgery and then at 1 month and again at 3 months after surgery, and the parameters measured were walking speed, stride length (SL), single limb support (SLS), cycle duration (CD), and swing power (SP). Harris Hip Scores and gait analysis parameters for both groups were compared. RESULTS Intraclass comparison indicated that Harris Hip Scores, speed scores, and gait parameter measures in both groups improved significantly with the passage of time; Interclass comparison showed no significance between Harris(1m postop) - Harris(preop) and Harris(3m postop) - Harris(preop) in both groups. The speed in the BHR group at 1 month and at 3 months after surgery was significantly higher than that of conventional group. At 1 month after surgery, each mean for SL(normal) - SL(affected), (SLS(normal) - SLS(affected))/CD, and SP(normal) - SP(affected) in the BHR group was significantly lower than that for the conventional group. At 3 months after surgery, the differences between means for both groups for SL(normal) - SL(affected), (SLS(normal) - SLS(affected))/CD, and SP(normal) - SP(affected) were not significant, but the mean of SP(normal) - SP(affected) in the BHR group was significantly lower than that in the conventional group. CONCLUSIONS Our data suggest that large-diameter femoral heads in THA provide better early gait restoration than conventional-size femoral heads.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Total Hip Arthroplasty and Core Decompression in Avascular Necrosis of the Femoral Head after Taking Temgesic and Norgesic

Background: Osteonecrosis is common after taking Temgesic and Norgesic. This study intended to suggest the preferable surgical treatment in osteonecrosis patients who use these drugs. Methods: Twenty tree patients with hip osteonecrosis who were hospitalized in the Kerman hospitals after using Temgesic and Norgesic were followed for about 14 months from 2008 to 2010 (from a minimum of 2 months ...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Late Disassembly of Femoral Head and Neck of A Modular Primary Total Hip Arthroplasty

INTRODUCTION Modular total hip arthroplasty system are now widely used, as these components increase the flexibility during primary and revision total hip arthoplasty. But this modularity itself associated with some risk of intraoperative and postoperative complications. CASE REPORT We report a case of late disassembly of a primary total arthroplasty in a 42 years old patient five years after...

متن کامل

Intrapelvic Dislocation of a Femoral Trial Head During Primary Total Hip Arthroplasty Requiring Laparotomy for Retrieval

BACKGROUND AND PURPOSE Total hip arthroplasty (THA) is a safe and reliable surgical procedure. However, THA also has intra- and postoperative complications. A dreaded and frustrating intraoperative complication during total hip arthroplasty is dislocation of the femoral trial head from the neck into the pelvis. METHODS Here, we report on the case of a 71-year old female patient with osteoarth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chinese medical journal

دوره 122 13  شماره 

صفحات  -

تاریخ انتشار 2009