Computed tomography scanogram compared to long leg radiograph for determining axial knee alignment

نویسندگان

  • Thomas J Holme
  • Johann Henckel
  • Kai Hartshorn
  • Justin P Cobb
  • Alister J Hart
چکیده

BACKGROUND AND PURPOSE Supine computed tomography scanogram (CTS) is a commonly used alternative to weight bearing long leg plain radiograph (LLR) in measuring knee alignment. No published studies have validated its use in the native knee and the post-unicompartmental replacement knee (UKR). We quantified the difference in measurements obtained from CTS and LLR for knee alignment. PATIENTS AND METHODS Supine CT scanograms and weight bearing long leg plain anteroposterior radiographs were obtained for 40 knees (in 25 patients), 17 of which were native, and 23 of which were post-UKR. The mechanical and anatomical axes of the tibio-femoral joint were measured. Bland-Altman plots were used to calculate the 1.96 standard deviation limits of agreement between CTS and LLR. Intraclass correlation was used to assess intra-rater and inter-rater reliability (where values > 0.81 indicate very good reliability). RESULTS CTS and LLR were equally reliable in measurement of the mechanical and anatomical axes of the tibio-femoral joint (intraclass correlation coefficient (ICC) > 0.9 for all parameters). Statistically significant and clinically relevant differences were found between CTS and LLR in measurement of the mechanical axis (limits of agreement: UKR -3.2° to 6.3°; native -3.2° to 5.6°) and the anatomical axis (limits of agreement: UKR -3.7° to 8.7°; native -2.0° to 8.8°). INTERPRETATION Although it is a reliable tool, CTS is not necessarily an accurate one for measurement of knee alignment when compared to LLR. We recommend that CTS should not be used as a substitute for LLR in measurement of the mechanical or anatomical axes of the knee.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis

BACKGROUND To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position. AIMS To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods. STUDY DES...

متن کامل

A comparative assessment of alternatives to the full-leg radiograph for determining knee joint alignment

UNLABELLED BACKGROUND The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs. METHODS The knee-alignment angle was measured in 100 knees of...

متن کامل

Radiation dose to breasts from a cardiac computed tomography angiographyscanogram can be reduced by switching tube position.

BACKGROUND/AIM In a computed tomography (CT) examination, scanogram images are used to determine the range of the area to be imaged before scanning. The importance of scanogram image exposure has increased since total examination radiation has decreased due to technological advancements. The purpose of this study was to determine and compare radiation doses delivered to patients while the tube ...

متن کامل

Kinematically versus mechanically aligned total knee arthroplasty.

The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conducted with the patient, radiographic evaluator, and clinical evaluator blinded to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2015