Unsteady discharge calibration of a large V-notch weir
نویسندگان
چکیده
Thin-plate weirs are commonly used as measuring devices in flumes and channels, enabling an accurate discharge measurement with simple instruments. The calibration formulae of such devices rely upon some empirical coefficients and there is a need to obtain new accurate physical data to complement the existing evidence. In the present study, the discharge calibration of a large 901 V-notch thin plate weir was performed using an unsteady volume per time technique. The V-notch weir was initially closed by a fast-opening gate. The sudden opening induced an initial phase of the water motion dominated by the free-falling motion of a volume of fluid in the vicinity of the weir, followed by a gradually-varied phase, during which some seiche was observed in the tank. The relationship between water discharge and upstream water elevation was derived from the integral form of the continuity equation. The results yielded a dimensionless discharge coefficient Cd1⁄40.58 close to previous experiments for 901 V-notch weirs. The findings showed that the unsteady discharge calibration of the V-notch weir yielded similar results to a more traditional calibration approach based upon steady flow experiments, allowing a rapid testing over a broad range of flow rates. & 2012 Elsevier Ltd. All rights reserved.
منابع مشابه
V-Notch Weir Overflow: an Unsteady Calibration
Thin-plate V-notch weirs are commonly used as measuring devices in flumes and channels. Herein, the discharge calibration of a large 90o V-notch weir was performed using an unsteady volume per time technique. The weir overflow was initially shut. The sudden opening of the gate was associated with an initial phase of transient water motion associated with a negative wave propagating in the reser...
متن کاملMathematical Model of Unsteady Groundwater Flow Through Aquifers and Calibration Via a Non-Linear Optimization Technique
In this study, the general partial differential equation of unsteady groundwater flow through non-homogeneous and anisotropic aquifer was solved by the fully implicit finite difference method with control volume approach. The calibration of permeability and storage coefficients as model parameters was performed by a transformation technique and application of Powell's non-linear optimization me...
متن کاملWeir Design and Calibration for Stream Monitoring in a Riparian Wetland
Accurate measurement of stream flow is an important component of environmental water quality monitoring. Flow rates in small streams can be conveniently monitored using weirs. The objective of this study was to design, install, and calibrate a series of permanent compound weirs for use in monitoring flow and water quality in a first order riparian wetland stream that exhibited great variability...
متن کاملA laboratory investigation on the potential of computational intelligence approaches to estimate the discharge coefficient of piano key weir
The piano key weir (PKW) is a type of nonlinear control structure that can be used to increase unit discharge over linear overflow weir geometries, particularly when the weir footprint area is restricted To predict the outflow passing over a piano key weir, the discharge coefficient in the general equation of weir needs to be known. This paper presents the results of laboratory model testing of...
متن کاملTwin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)
For efficient use of water, accurate measurement of flow in (field/laboratory) channels is required for many water resource projects. The present work is aimed to study the flow characteristics of a twin plate weir (two sharp-crested plates are placed one behind the other at some distance) under free and submerged flow conditions. Experiments are performed with four spacing of the twin plate we...
متن کامل