Aortic Valve Reconstruction Using Autologous Pericardium for Aortic Stenosis.

نویسندگان

  • Shigeyuki Ozaki
  • Isamu Kawase
  • Hiromasa Yamashita
  • Shin Uchida
  • Mikio Takatoh
  • So Hagiwara
  • Nagaki Kiyohara
چکیده

BACKGROUND To determine the feasibility of original aortic valve reconstruction (AVRec) for patients with aortic stenosis (AS), 416 consecutive cases were reviewed. METHODS AND RESULTS AVRecs for AS were performed for 416 patients from April 2007 through April 2013. All 416 patients were retrospectively reviewed. One hundred and fourteen patients had bicuspid valves and 16 had unicuspid valves. There were 182 men and 234 women. Mean age was 71.2±12.0 years old. On preoperative echocardiography, peak pressure gradient averaged 79.0±33.6 mmHg. Surgical annular diameter was 20.1±2.8 mm. The procedure is based on independent tricuspid replacement by autologous pericardium using original sizing apparatus and template. There was no conversion to prosthetic valve replacement. There were 8 in-hospital mortalities due to non-cardiac cause. On postoperative echocardiography, peak pressure gradient averaged 21.2±10.7 mmHg 1 week after surgery and 14.3±5.0 mmHg 5.5 years after surgery. Four reoperations were done for infective endocarditis. The other 412 patients had less than mild regurgitation. No thrombo-embolic events were recorded. The mean follow-up period was 25.2±17.5 months. Freedom from reoperation was 96.7% with 73-month follow-up. CONCLUSIONS Medium-term results were excellent. Original AVRec was feasible for the patients with AS. Long-term data will be presented in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

esults of Aortic Valve-Sparing and Restoration ith Autologous Pericardial Leaflet Extensions in ongenital Heart Disease

Background. The purpose of this study is to evaluate he efficacy of aortic valve-sparing repair with glutaralehyde-treated autologous pericardium in congenital alvular pathology. Methods. Sixty-two patients underwent reparative aoric valve surgery from January 1997 through December 003. The mean age was 25 20 years ( standard eviation) (range, 10 days to 81 years). Fifty percent (31 of 2) were ...

متن کامل

Tricuspid valve repair using autologous pericardium annuloplasty in adults.

Uncorrected functional tricuspid regurgitation can lead to long-term morbidity and mortality. To evaluate our results using autologous pericardium annuloplasty to treat tricuspid regurgitation, we retrospectively reviewed 59 consecutive adult patients aged 19 years to 83 years (58.7 +/- 15.5 years) who underwent tricuspid valve annuloplasty between 2000 and 2003. Concomitant procedures consiste...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Pericardial patch augmentation for repair of incompetent bicuspid aortic valves at midterm.

OBJECTIVE Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves. METHODS Autologous pericardium is sutured to the free edge of the prolapsing bicuspid leaflet. A large coaptation ...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 79 7  شماره 

صفحات  -

تاریخ انتشار 2015