Fragrance mix I patch test reactions in 5006 consecutive dermatitis patients tested simultaneously with TRUE Test® and Trolab® test material.
نویسندگان
چکیده
BACKGROUND The prevalence of contact allergy to fragrance mix (FM) I varies from study to study, depending on factors such as test population, patch test material, and technique. OBJECTIVES To compare the outcome of routine patch testing with FM I TRUE Test and FM I Trolab. MATERIALS AND METHODS A total of 5006 consecutive eczema patients were patch tested with both patch test materials according to the International Contact Dermatitis Research Group. RESULTS A total of 9.9% patients tested had a positive reaction to one of the FM I mixes; 4.4% to FM I TRUE Test, 9.3% to FM I Trolab, and 3.7% to both (P < 0.0001). Patients with a stronger reaction to FM I TRUE Test almost all reacted to FM I Trolab, whereas the reverse situation showed a lower association. Clinical relevance of a positive patch test reaction to FM I TRUE Test was found in 73.0%, and clinical relevance of a positive patch test reaction to FM I Trolab was found in 64.3%; 68.4% of the patients with a positive reaction to FM I TRUE Test and 54.3% with a positive reaction to FM I Trolab were positive to one or more of the eight constituents of the mix. LIMITATIONS The study is retrospective, and supplementary testing with FM components in patients with a positive reaction to the mixes was performed in a selected group of patients. Determination of clinical relevance may be biased. CONCLUSIONS From this study, we cannot conclude which of the two FM I test preparations is the best for diagnostic purposes. Inclusion of both FM I tests in the baseline series to obtain a graded degree of FM I allergy for the individual patient is one option. Prospective controlled patch test studies with FM I patch test material are recommended.
منابع مشابه
Frequency of false positive responses in patients with multiple positive reactions in patch test
Background and aim: Contact dermatitis is an inflammatory skin response due to contact with environmental materials manifested as acute or chronic eczema. Patch test is the standard test to recognize responsible allergen. The objective of this study was to evaluate the frequency of false positive patch test responses in patients with Exited Skin Syndrome (ESS).Materials...
متن کاملPositive patch test reactions to nickel sulphate are not modified by neighbouring negative fragrance patch tests. A multicenter-study by the German contact dermatitis research group.
It is tacitly assumed that a positive patch test reaction is not affected by adjacent negative tests. However, despite its fundamental importance for the interpretation of test reactions this assumption has not been proven. To test this assumption, special TRUE-test strips were prepared containing placebo, nickel sulphate and fragrance mix as the only allergens, separated by distances of 1 cm a...
متن کاملReactivity to sorbitan sesquioleate affects reactivity to fragrance mix I.
BACKGROUND Fragrance mix I (FM I) and its single constituents contain 5% and 1% sorbitan sesquioleate (SSO), respectively. SSO is a rare sensitizer and a potential irritant. OBJECTIVES To determine whether the outcome of the FM I breakdown test is affected by positive patch test reactivity to SSO. METHODS A retrospective analysis of data from the Information Network of Departments of Dermat...
متن کاملRecommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.
BACKGROUND The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. OBJECTIVE To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, c...
متن کاملPatch testing with fragrance mix II: results of the IVDK 2005-2008.
BACKGROUND The fragrance mix (FM I), established in 1977, detects the majority, but not all cases of contact allergy to fragrances. Based on European research 2002/2003, fragrance mix II (FM II) was developed to supplement FM I. In 2005, the German Contact Dermatitis Research Group (DKG) added FM II to their baseline series. OBJECTIVES To evaluate reactions to FM II and its constituents in ro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Contact dermatitis
دوره 63 5 شماره
صفحات -