Cost-effectiveness of dual-chamber pacing compared with ventricular pacing for sinus node dysfunction.
نویسندگان
چکیده
BACKGROUND Compared with single-chamber ventricular pacing, dual-chamber pacing can reduce adverse events and, as a result, improve quality of life in patients paced for sick sinus syndrome. It is not clear, however, how these benefits compare with the increased cost of dual-chamber pacemakers. METHODS AND RESULTS We used 4-year data from a 2010-patient, randomized trial to estimate the incremental cost-effectiveness of dual-chamber pacing compared with ventricular pacing and then projected these findings over the patients' lifetimes by using a Markov model that was calibrated to the first 5 years of in-trial data. To assess the stability of the findings, we performed 1000 bootstrap analyses and multiple sensitivity analyses. During the first 4 years of the trial, dual-chamber pacemakers increased quality-adjusted life expectancy by 0.013 year per subject at an incremental cost-effectiveness ratio of 53,000 dollars per quality-adjusted year of life gained. Over a lifetime, dual-chamber pacing was projected to increase quality-adjusted life expectancy by 0.14 year with an incremental cost-effectiveness ratio of approximately 6800 dollars per quality-adjusted year of life gained. In bootstrap analyses, dual-chamber pacing was cost-effective in 91.9% of simulations at a threshold of 50,000 dollars per quality-adjusted year of life and in 93.2% of simulations at a threshold of 100,000 dollars. Its cost-effectiveness ratio was also below this threshold in numerous sensitivity analyses that varied key estimates. CONCLUSIONS For patients with sick sinus syndrome requiring pacing, dual-chamber pacing increases quality-adjusted life expectancy at a cost that is generally considered acceptable.
منابع مشابه
Ventricular pacing or dual-chamber pacing for sinus-node dysfunction.
BACKGROUND Dual-chamber (atrioventricular) and single-chamber (ventricular) pacing are alternative treatment approaches for sinus-node dysfunction that causes clinically significant bradycardia. However, it is unknown which type of pacing results in the better outcome. METHODS We randomly assigned a total of 2010 patients with sinus-node dysfunction to dual-chamber pacing (1014 patients) or v...
متن کاملRole of permanent pacing to prevent atrial fibrillation: science advisory from the American Heart Association Council on Clinical Cardiology (Subcommittee on Electrocardiography and Arrhythmias) and the Quality of Care and Outcomes Research Interdisciplinary Working Group, in collaboration with the Heart Rhythm Society.
This advisory summarizes the current database on pacing modalities and algorithms used to prevent and terminate atrial fibrillation (AF). On the basis of the evidence indicating that ventricular pacing is associated with a higher incidence of AF in patients with sinus node dysfunction, a patient who has a history of AF and needs a pacemaker for bradycardia should receive a physiological pacemak...
متن کاملDual chamber pacing mode in an atrial antitachycardia pacing device without a ventricular lead - A necessary evil.
We present a case of a single chamber atrial pacemaker implanted for sinus node dysfunction and treatment of macroreentrant atrial tachycardias with atrial antitachycardia pacing. The patient presented with sustained atrial tachycardia above the detection rate, however, the device was unable to detect the tachycardia and did not deliver the programmed therapy. We discuss the nuances of the atri...
متن کاملClosed loop stimulation improves ejection fraction in pediatric patients with pacemaker and ventricular dysfunction.
BACKGROUND The aim of this prospective study was to evaluate the effect of the closed loop stimulation (CLS) on the ejection fraction in pediatric patients, affected by complete atrioventricular block (CAVB) or CAVB and sinus node dysfunction (SND), with a previously implanted pacemaker (PM) and ventricular dysfunction. The role of electrical therapy in the treatment of pediatric patients with ...
متن کاملAdverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction.
BACKGROUND Dual-chamber (DDDR) pacing preserves AV synchrony and may reduce heart failure (HF) and atrial fibrillation (AF) compared with ventricular (VVIR) pacing in sinus node dysfunction (SND). However, DDDR pacing often results in prolonged QRS durations (QRSd) as the result of right ventricular stimulation, and ventricular desynchronization may result. The effect of pacing-induced ventricu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 111 2 شماره
صفحات -
تاریخ انتشار 2005