Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water

نویسندگان

  • Wacław Janicki
  • Wojciech Chrzanowski
  • Andrzej Wasik
  • Elżbieta Przyk
  • Jacek Namieśnik
چکیده

An automated analyser of volatile chloro-organic compounds in water was constructed and tested using standard mixtures of dichloromethane and dichloroethane. It was based on continuous, countercurrent gas stripping of the liquid sample followed by periodic trapping of the analytes on two traps alternately connected to the bubbler outlet, and thermal desorption. When one trap performed adsorption, the other underwent desorption and cooling. Analytes were detected by an ECD detector. Integration, calibration, calculations and overall operating cycle control was performed by a microcomputer. The instrument guarantees a 0.02 ppm Cl (w/w) detection limit, a 0-2 ppm detection range and 2 months of autonomous operation. Results are reported every 13 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring and Zoning of PM2.5, PM10 and VOCs Concentration in Air of Gorgan City in 2016

Background & Aim: Increasing of air pollution in cities seriously threatens the health of its inhabitants.  PM2.5, PM10 and volatile organic compounds are amongst the air pollutants that their existence in the air in excess concentrations, leads to respiratory and cardiovascular problems, cancer and mortality. Therefore, the concentration of these pollutants in the air of Gorgan city was measur...

متن کامل

A Turn-key Analyser Solution for the Target Based Screening of Environmental Water Samples on the Agilent 5977 Gc/ms

Agilent is now offering a comprehensive analyser package for the target based, multiresidue screening of environmental waters on the Agilent 5977 GC/MS. This screening method uses Target Deconvolution (TD) on the MassHunter Quantitative software. It is suitable for the analysis of environmental waters as required by the Water Framework Directive (WFD 2000/60/EC). This method uses a target MS li...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

New Concepts and Techniques for Quantification and Trace Analysis by Gas Chromatography

In the first part of this thesis, strategies for avoiding systematic errors when quantifying the main components in mixtures of solvents has been developed (paper I). It is shown that variations in density caused by variations in sample composition and/or volume contraction need to be taken into account. In this way, quantification can be improved. The second part (paper II-V) describes a numbe...

متن کامل

Performance analysis of Zinc oxide based alcohol sensors

Sensor technology is one of the most significant technology for the future with a constantly growing number of applications, ranging from toxic gas detection, manufacturing process monitoring to medical diagnosis and health monitoring. Among the different existing sensor technologies, the semiconductor sensors are most attractive for their high sensitivity, small size and light-weight construct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2002