Validation of the POLY-MESAM seven-channel ambulatory recording unit.

نویسندگان

  • T Verse
  • W Pirsig
  • B Junge-Hülsing
  • B Kroker
چکیده

STUDY OBJECTIVES To determine the recording capabilities of the POLY-MESAM (PM) unit (MAP; Martinsried, Germany), an American Sleep Disorders Association level III system, and to compare it with simultaneous 12-channel polysomnography in the sleep laboratory. MEASUREMENTS AND RESULTS Fifty-three patients (49 men and 4 women) with obstructive sleep-related breathing disorders of varying severity were included. The apnea-hypopnea indexes (AHIs) obtained using the two methods differed significantly from each other, although the correlation was close. The PM unit produced false-negative results in patients with mild to moderate obstructive sleep apnea (OSA). The sensitivity of the PM unit in detecting patients with an AHI > 10 was 92%, while the specificity was 96.3%. CONCLUSIONS The correlation of AHIs obtained with polysomnography and with the PM unit is close. However, in some cases, the PM may underestimate OSA parameters. The PM unit produces false-negative results in patients with mild to moderate OSA. While inpatient polysomnography remains the "gold standard," the PM unit may provide an inexpensive alternative in some special cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome.

The current study investigated the night-to-night variability and diagnostic accuracy of the oxygen desaturation index (ODI), as measured by ambulatory monitoring, in the diagnosis of mild and moderate obstructive sleep apnoea-hypopnoea syndrome. To assess the variability of the ODI, 35 patients were monitored at home during 7 consecutive nights by means of a portable recording device, the MESA...

متن کامل

Simplified diagnostic procedure for obstructive sleep apnoea syndrome: lower subsequent compliance with CPAP.

The aim of this study was to investigate whether a simplified diagnostic procedure based on ambulatory monitoring with MESAM IV altered subsequent compliance with continuous positive airway pressure (CPAP) in obstructive sleep apnoea (OSA) patients. During a period of 16 months, 60 patients with symptoms evocative of OSA and positive MESAM recording were prescribed CPAP after titration with sta...

متن کامل

Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome.

BACKGROUND Portable devices are used for unattended recording of patients with suspected obstructive sleep apnea syndrome (OSAS). The MESAM 4 (MAP; Martinsried, Germany) is a computerized ambulatory polysomnographic system that records four parameters: breathing noise, heart rate, arterial oxygen saturation (SaO(2)), and body position. DESIGN AND METHOD We evaluated the reliability of the oxy...

متن کامل

Snoring and nocturnal oxygen desaturations in an Italian middle-aged male population. Epidemiologic study with an ambulatory device.

Recent studies have suggested that portable monitoring may be a valid means of finding respiratory disturbances in epidemiologic research on a large scale. The aim of this cross-sectional study was to evaluate by means of an appropriately validated portable instrument (MESAM 4) the nocturnal oxygen desaturations in a representative sample of adult male population in North Italy. We randomly cho...

متن کامل

Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea.

This study evaluated the accuracy of a portable recording device (MESAM IV) in identifying obstructive sleep apnoea (OSA). The MESAM IV system measures arterial oxygen saturation (Sa,O2), heart rate, snoring sounds and body position, and allows both automatic and manual scoring of the recordings. Nocturnal polysomnography and MESAM IV recordings were performed simultaneously in 150 patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 117 6  شماره 

صفحات  -

تاریخ انتشار 2000