Transforming hemoglobin measurement in trauma patients: noninvasive spot check hemoglobin.
نویسندگان
چکیده
BACKGROUND Technological advances now allow for noninvasive Hbg measurements. Previous studies have reported on the efficacy of continuous noninvasive Hgb devices. Recently, a new device, Pronto-7, a spot check pulse CO-oximeter has become available. The aim of our study was to assess noninvasive Hgb measurement in trauma patients. METHODS We performed a prospective cohort analysis of all trauma patients presenting to our Level I trauma center. Invasive Hgb and spot check Hgb measurements were obtained simultaneously at presentation. Spot check was measured 2 times with each invasive Hgb value. Normal Hgb was defined as >8 mg/dL. Spearman correlation and Bland-Altman analysis was performed. RESULTS A total of 525 patients had attempted spot check Hgb measurements with a success rate of 86% (n = 450). A total of 450 invasive and 1,350 spot check Hgb measurements were obtained. Mean ± SD age was 41 ± 21 years, 74% were male, and mean Injury Severity Score was 21 ± 13. Thirty-eight percent (n = 173) of patients had Hgb ≤8 mg/dL at presentation. Mean invasive Hgb was 11.5 ± 4.36 g/dL, mean spot check Hgb 11.1 ± 3.60 g/dL, and mean difference was 0.3 ± 1.3 g/dL. Spot check Hgb values had strong correlation with invasive Hgb measurements (R(2) = 0.77; R = 0.86; p = 0.04) with 76% accuracy and 95.4% sensitivity. CONCLUSIONS Spot check Hgb monitoring had excellent correlation with invasive Hgb measurements. Application of spot check has more clinical use as compared with previous continuous Hgb monitoring. This novel technology allows immediate and accurate Hgb measurements in trauma patients.
منابع مشابه
Assessing serum hemoglobin levels without venipuncture: accuracy and reliability of Pronto-7 noninvasive spot-check device.
BACKGROUND Hemoglobin is a frequently obtained test in hospital settings. We analyzed accuracy of a noninvasive device compared to standard laboratory analyzers in a variety of settings. METHODS A noninvasive hemoglobin monitoring device was analyzed for reliability, correlation, precision, and bias. Hemoglobin levels were obtained from standard laboratory and point-of-care hemoglobin analyze...
متن کاملAccuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer
INTRODUCTION Hemoglobin concentration is assessed to detect anemia and its associated morbidities. Hemoglobin is usually determined from venous or capillary blood samples run on a laboratory analyzer. However, this method requires a needle stick and results can be delayed. It also exposes caregivers to risks associated with needle sticks and blood exposure. Noninvasive hemoglobin determination ...
متن کاملNoninvasive Assessment of Excessive Erythrocytosis as a Screening Method for Chronic Mountain Sickness at High Altitude.
Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162-168, 2015.--Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to l...
متن کاملTrending, Accuracy, and Precision of Noninvasive Hemoglobin Monitoring During Human Hemorrhage and Fixed Crystalloid Bolus.
Automated critical care systems for en route care will rely heavily on noninvasive continuous monitoring. It has been reported that noninvasive assessment of blood hemoglobin via CO-oximetry (SpHb) assessed by spot measurements lacks sufficient accuracy for clinical decision making in trauma patients. However, the precision and utility of trending of continuous hemoglobin have not been evaluate...
متن کاملAccuracy of noninvasive and continuous hemoglobin measurement by pulse co-oximetry during preoperative phlebotomy.
BACKGROUND In recent years, the continuous noninvasive hemoglobin measurement has been offered by devices using advanced pulse oximetry technology. Accuracy has been established in healthy adults as well as in surgical and intensive care unit patients but not in the setting of acute hemorrhage. In this study, we evaluated the accuracy of such a device in the clinical setting of preoperative phl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Surgeons
دوره 220 1 شماره
صفحات -
تاریخ انتشار 2015