Development and validation of an analytical methodology for the detection and quantification of amoxicillin in meat, by LC-MS/MS
نویسندگان
چکیده
The development and validation of an analytical methodology, based on liquid chromatography tandem mass spectrometry (LC-MS/MS), was set up for the detection and quantification of amoxicillin in meat. The method consists of a simple extraction with phosphate buffer (pH 8.2) with sodium chloride followed by purification by solid phase extraction on OASIS HLB. During validation, according to the established European Union requirements, the following limits for amoxicillin were set: detection limit (LD) of 5 μg/kg and quantification limit (LQ) of 8 μg/kg. The decision limit (CCα) and the capacity of detection (CCβ) obtained for amoxicillin were 56 μg/kg and 67 μg/kg. A stability study was conducted, under pH and temperature variations, with the goal of better understand amoxicillin degradation and characterize its main products (amoxicilloic acid and amoxicillin diketopiperazine). Key-words: Amoxicillin, LC-MS/MS, validation, meat
منابع مشابه
Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملValidation of the analysis method of 25 pesticide residues in rice using LC-MS/MS device (liquid chromatography-mass spectrometry)
Introduction: In recent years, due to the increase in the use of pesticides in agricultural products and its entry into the human food chain, there has been an increase in concerns about the health of food among people. Therefore, the purpose of conducting this research is to validate the analysis method. 25 pesticide residues in rice using LC-MS/MS. Methods: In this research, a simultaneous an...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملValidation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column
This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...
متن کاملValidation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column
This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...
متن کامل