Granisetron showed one well-defined reduction peak at Hanging Mercury Drop Electrode (HMDE) in the potential range from -1.3 to -1.5 V due to reduction of C=N bond. Solid-phase extraction technique was employed for extraction of Granisetron from spiked human plasma. Granisetron showed peak current enhancement of 4.45% at square-wave voltammetry and 5.33% at cyclic voltammetry as compared with the non stripping techniques. The proposed voltammetric method allowed quantification of Granisetron in pharmaceutical formulation over the target concentration range of 50-200 ng/mL with detection limit 13.63 ng/mL, whereas in human plasma 50-225 ng/mL with detection limit 11.75 ng/mL.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid

In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...

متن کامل

Determination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange

Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...

متن کامل

Adsorptive Cathodic Stripping Voltammetric Determination of Ciprofloxacin in Bulk Powder, Pharmaceutical Dosage Forms and Urine

Purpose: To investigate the electro-reduction behaviour and determination of ciprofloxacin using a hanging mercury drop electrode. Methods: Cyclic voltammograms of ciprofloxacin recorded in Britton – Robinson buffers pH 2 – 5 exhibit a single irreversible cathodic peak. The dependence of the peak current and peak potential values on buffer (nature, pH and concentration) and accumulation conditi...

متن کامل

A Validated Adsorptive Stripping Voltammetric Determination of Antidiabetic Agent Pioglitazone HCl in Tablets and Biological Fluids

Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs. Ag/AgCl. The peak response was characterized with respect to pH, supporting electrolyte, frequency, scan increment, pulse-amplitude, accumulation potential and pre-concentration time. Under optimal conditions, the...

متن کامل

Differential pulse and square-wave cathodic stripping voltammetry of xanthine and xanthosine at a mercury electrode.

The surface activity of xanthine (Xan) and xanthosine (Xano) at a hanging mercury drop electrode (HMDE) was studied using out-of-phase ac and cyclic dc voltammetry. The results show that Xan and Xano were strongly adsorbed and chemically interacted with the charged mercury surface, which is the prerequisite step for applying the cathodic adsorptive stripping voltammetric determination of such b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012