An experiment investigating the photoelectron instability has been performed in BEPC at IHEP, China. The betatron oscillation of each bunch was observed and recorded by a single pass beam position monitor system which has a capability to measure the transverse position of every bunch over 16000 turns. The effect of an octupole magnet on the instability was also studied. This paper describes results of those observations and analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Proposed Experimental Study on Beam- Photoelectron Interactions in Bepc

A vertical collective effect suspected as photoelectron instability (PEI) has been observed at Photon Factory (PF) of KEK in recent years. This phenomena may impose a limitation on the performance of the proposed B-Factories or T-c Factories. An experiment has been planned to test it using positron beam at Beijing Electron Positron Collider (BEPC) in 1996 under the cooperation between IHEP and ...

متن کامل

Photoemission Instabilities: Theory and Experiment

Synchrotron radiation in electron-positron colliders and synchrotron light sources ejects photoelectrons from the beam chamber walls. The resulting cloud of slow photoelectrons interacts with the beam, and may generate a transverse coupled bunch instability. In some high current storage rings a photoemission effect causes the dominant transverse instability, with a sub-millisecond risetime. Two...

متن کامل

Operational Status and Future Upgrades of Bepc

In this paper the operational status of Beijing ElectronPositron Collider(BEPC) in recent years is described. The luminosity upgrades have been performed in recent years. By lowering the vertical E function at interaction point the peak luminosity is nearly doubled. The single interaction point in BEPC is also studied experimentally. The results show that beam-beam tune shifts decrease signific...

متن کامل

The Electron Cloud Instability Studies in Bepc*

The electron cloud instability (ECI) in the BEPC was studied systematically with experiments and simulations in recent years. Several electron cloud detectors have been installed into the BEPC storage ring to measure the electron yielding. The effects of solenoid, the clearing electrode, the chromaticity and the octupole on ECI have been investigated in BEPC experimentally. To evaluate the ECI ...

متن کامل

The beam energy calibration system for the BEPC - II collider

This document contains a proposal of the BEPC-II collider beam energy calibration system (IHEP, Beijing). The system is based on Compton backscattering of carbon dioxide laser radiation, producing a beam of high energy photons. Their energy spectrum is then accurately measured by HPGe detector. The high-energy spectrum edge will allow to determine the average electron or positron beam energy ε ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999