Tolerance of arteries to microplanar X-ray beams.

نویسندگان

  • Boudewijn van der Sanden
  • Elke Bräuer-Krisch
  • Erik Albert Siegbahn
  • Clément Ricard
  • Jean-Claude Vial
  • Jean Laissue
چکیده

PURPOSE The purpose is to evaluate effects of a new radiotherapy protocol, microbeam radiation therapy, on the artery wall. In previous studies on animal models, it was shown that capillaries recover well from hectogray doses of X-rays delivered in arrays of narrow (< or = 50 microm) beams with a minimum spacing of 200 microm. Here, short- and long-term effects of comparable microplanar beam configurations on the saphenous artery of the mouse hind leg were analyzed in situ by use of nonlinear optics and compared with histopathologic findings. METHODS AND MATERIALS The left hind leg of normal mice including the saphenous artery was irradiated by an array of 26 microbeams of synchrotron X-rays (50 microm wide, spaced 400 microm on center) with peak entrance doses of 312 Gy and 2,000 Gy. RESULTS The artery remained patent, but narrow arterial smooth muscle cell layer segments that were in the microplanar beam paths became atrophic and fibrotic in a dose-dependent pattern. The wide tunica media segments between those paths hypertrophied, as observed in situ by two-photon microscopy and histopathologically. CONCLUSIONS Clinical risks of long-delayed disruption or occlusion of nontargeted arteries from microbeam radiation therapy will prove less than corresponding risks from broad-beam radiosurgery, especially if peak doses are kept below 3 hectograys.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interlaced x-ray microplanar beams: a radiosurgery approach with clinical potential.

Studies have shown that x-rays delivered as arrays of parallel microplanar beams (microbeams), 25- to 90-microm thick and spaced 100-300 microm on-center, respectively, spare normal tissues including the central nervous system (CNS) and preferentially damage tumors. However, such thin microbeams can only be produced by synchrotron sources and have other practical limitations to clinical impleme...

متن کامل

High-Precision Radiosurgical Dose Delivery by Interlaced Microbeam Arrays of High-Flux Low-Energy Synchrotron X-Rays

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very h...

متن کامل

Megavoltage X-ray Dose Enhancement with Gold Nanoparticles in Tumor Bearing Mice

One of the applications of gold nanoparticles (GNPs) in medicine is radiation dose-enhancing effect. Although there are many simulations, in vitro and in vivo evidence that GNPs can enhance significantly the radiation dose effect of orthovoltage beams. These beams compared with megavoltage (MV) beams, have limited applications in radiotherapy. In order to evaluate GNPs radiosensitization perfor...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 77 5  شماره 

صفحات  -

تاریخ انتشار 2010