Serum C-reactive protein concentration in the management of infection in patients treated by continuous ambulatory peritoneal dialysis.
نویسندگان
چکیده
In a prospective study over 21 months, serum C-reactive protein (CRP) concentration was measured serially in 39 consecutive patients undergoing continuous ambulatory peritoneal dialysis. All patients with peritonitis mounted a CRP response, and the height of the response correlated well with the severity and extent of the peritoneal damage. Patients who recovered uneventfully after antimicrobial treatment showed a prompt fall in CRP from its peak value towards normal. In contrast, each patient in whom the serum CRP value remained raised after antimicrobial treatment had a complicated course. During routine outpatient follow up the serum CRP value remained within the normal range in the absence of intercurrent complications. These results, together with the commercial availability of rapid and precise assays for CRP, indicate that serial CRP measurements may be useful in monitoring the efficacy of antimicrobial treatment during episodes of peritonitis and in the recognition of intercurrent complications in patients undergoing continuous ambulatory peritoneal dialysis.
منابع مشابه
Correlation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift
Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...
متن کاملRelationship between serum albumin and pulse wave velocity in patients on continuous ambulatory peritoneal dialysis
BACKGROUND Hypoalbuminemia is a risk factor for cardiovascular events and mortality in dialysis patients, but the underlying mechanism remains unclear. Meanwhile, increased pulse wave velocity (PWV), the marker of arterial stiffness, has been proved to be an independent predictor of cardiovascular disease. The relationship between serum albumin and PWV in continuous ambulatory peritoneal dialys...
متن کاملThe Relation Between Hypoalbuminemia and Compliance and Intima-media Thickness of Carotid Artery in Continuous Ambulatory Peritoneal Dialysis Patients
The aim of this study was to identify the main factor affecting compliance and intima-media thickness of the elastic common carotid artery in continuous ambulatory peritoneal dialysis patients. Increased intima-media thickness and decreased arterial compliance are associated with elevated risk of cardiovascular disease. This study included 20 patients and 20 age- and sex- matched healthy contro...
متن کاملارایه مدلی جهت پیشبینی بقای بیماران دیالیز صفاقی با استفاده از الگوریتمهای دادهکاوی
Background: Peritoneal dialysis is one of the most commonly used treatment methods for the patients with end stage renal failure. In recent years, the mortality rate of patients under this treatment has decreased; however, long-term survival is still an important challenge for health systems. The present study aimed to predict the survival of continuous ambulatory peritoneal dialysis patients. ...
متن کاملSerum albumin level as an indicator of response to Hepatitis B vaccination in dialysis patients: A systematic review and meta-analysis
Background: Hepatitis B (HB) vaccination is a recommended procedure in all dialysis patients, but its efficacy has not been perfect. In the current study, we aimed to conduct a comprehensive review of the literature to find and pool data of the randomized trials evaluating the impact of serum albumin levels on the immunogenicity of HB vaccination in dialysis patients. Methods: Literature searc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 38 4 شماره
صفحات -
تاریخ انتشار 1985