Real time affinity biosensor onto insulated polymer using electric impedance spectroscopy in dielectric microchip
نویسندگان
چکیده
Statistical study In general 3 experiments were taken into account in order to calculate dispersion parameters as standard deviation and variation coefficient (RSD). The last column in Table S1 shows the percentage variation of the interfacial impedance modulus when recognition reaction was taking place. Indeed the interfacial impedance variation on a surface coated with BSA is in a linear relationship with added Ab-BSA.
منابع مشابه
Dynamics of BSA adsorption onto a photoablated polymer surface in a dielectric microchip.
Dielectric impedance spectroscopy in a microchip was used for monitoring the adsorption of biomolecules onto a heterogeneous polymer surface obtained after the photoablation process. The sensor comprises a thin dielectric layer with two parallel carbon microband electrodes on the one side, and the photoablated surface on the other. The biomolecules need not to be labelled, as in an optical bios...
متن کاملStructural, Electrical, and impedance spectroscopy studies of Barium substituted nano calcium ferrites synthesized by solution combustion method.
Barium substituted nanocrystalline ferrites with chemical composition BaxCa1-xFe2O4 (x =0.0 to 0.25) BCAF were prepared by solution combustion method. The phase formation of mixed spinal structured ferrites was confirmed by PXRD analysis. The average crystallite size was calculated using Debye-Scherrer formula and it was found to be in the range of 27-44 nm. Surface morphology was analyzed by S...
متن کاملMicrofluidic Electric Impedance Spectroscopy for Malaria Diagnosis
This paper presents a label-free and noninvasive cell-counting assay system for electrical diagnostic tests of Falciparum malaria using electric impedance spectroscopy (EIS). Our system enabled a high-throughput test in a compact form-factor by the integration of a microfluidic device and a custom circuit board. Based on the differentiation of dielectric properties between cells and container m...
متن کاملFlexible Molybdenum Electrodes towards Designing Affinity Based Protein Biosensors
Molybdenum electrode based flexible biosensor on porous polyamide substrates has been fabricated and tested for its functionality as a protein affinity based biosensor. The biosensor performance was evaluated using a key cardiac biomarker; cardiac Troponin-I (cTnI). Molybdenum is a transition metal and demonstrates electrochemical behavior upon interaction with an electrolyte. We have leveraged...
متن کاملImmunobiosensor chips for detection of Escherichia coil O157:H7 using electrochemical impedance spectroscopy.
Impedance biosensor chips were developed for detection of Escherichia coli O157:H7 based on the surface immobilization of affinity-purified antibodies onto indium tin oxide (ITO) electrode chips. The immobilization of antibodies onto ITO chips was carried out using an epoxysilane monolayer to serve as a template for chemical anchoring of antibodies. The surface characteristics of chips before a...
متن کامل