Fracture Strength of Implant-Supported Ceramic Crowns with Customized Zirconia Abutments: Screw Retained vs. Cement Retained.

نویسندگان

  • Lorenna Bastos Lima Verde Nogueira
  • Carmem Dolores Vilarinho Soares Moura
  • Carlos Eduardo Francischone
  • Valdimar Silva Valente
  • Suyá Moura Mendes Alencar
  • Walter Leal Moura
  • Gregorio Antonio Soares Martins
چکیده

PURPOSE To compare the fracture resistance before and after cyclic fatigue assays of ceramic crowns with customized zirconia abutments when screw retained and cemented onto implants. MATERIALS AND METHODS The sample of this study consisted of 40 ceramic crowns with zirconia infrastructure fixed onto external hexagonal implants. The crowns were distributed into two groups (n = 20): Screw-retained and cemented crowns. Half the crowns of each group (n = 10) underwent compression until fracture and the other half (n = 10) underwent cyclic fatigue and subsequent compression until fracture. The cyclic fatigue test was carried out using an electromechanical fatigue device (loads from 0 to 100 N, 2 Hz frequency, in distilled water, at 37 °C for a period of 1 million cycles). The compression test was carried out using a universal testing machine with a 0.5 mm/min speed and 5 KN load cell. After fracture, the crowns were classified according to the type of fracture. Student's t test (p < 0.05) was used for statistical analysis. RESULTS The cyclic fatigue altered neither the mean fracture resistance of the screw-retained crowns (before = 1068.31 N, after = 891.49 N; p > 0.05) nor that of the cemented crowns (before = 2117.78 N; after = 2094.81 N; p > 0.05); however, the mean fracture resistance of the cemented crowns was higher than that of the screw-retained crowns both before (p < 0.001) and after (p < 0.001) the cyclic fatigue. Fractures occurred most frequently in the ceramic veneer, followed by fracture of some of the copings. CONCLUSION The ceramic crowns cemented onto the customized zirconia abutments offered greater fracture resistance than ceramic crowns with customized zirconia abutments screw retained onto implants. The cyclic fatigue did not seem to influence the fracture resistance of these crowns, whether cemented or screw retained onto implants. Fracture of the veneering ceramic was the predominant failure in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CAD/CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study.

BACKGROUND This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD/CAM, CEREC3D((R)) system. METHODS Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, m...

متن کامل

The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns

STATEMENT OF THE PROBLEM One disadvantage of cement-retained crowns is the lack of predictable irretrievability. This problem can be overcome through designing a screw access hole in the metal substructure of cement-retained restoration and using porcelain stain to define this area. PURPOSE This study aimed to evaluate the influence of existence of screw access hole on porcelain fracture resi...

متن کامل

Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

Background. Fracture load of implant-supported restorations is an important factor in clinical success. This study evaluated the effect of two techniques for screw access hole preparation on the fracture load of cement-screw-retained implant-supported zirconia-based crowns. Methods. Thirty similar cement-screw-retained implant-supported zirconia-based maxillary central incisor crowns were evalu...

متن کامل

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

PURPOSE The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design...

متن کامل

Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments.

This in vitro study quantified the marginal discrepancy of the implant-to-prosthetic-crown interface on nonsubmerged dental implants restored with either a cemented or a screw-retained approach. Metal-ceramic crowns were fabricated for 20 ITI 4.1 x 10 mm solid-screw titanium implants. Ten implants received octa abutments and screw-retained crowns fabricated on premachined gold cylinders. The re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 2016