Relationship between plasma concentration and dose of digoxin in patients with and without renal impairment.

نویسندگان

  • R D Okada
  • W D Hager
  • P E Graves
  • M Mayersohn
  • D G Perrier
  • F I Marcus
چکیده

The purpose of this study was to determine if there is a linear relationship between oral doses of digoxin and various measurements of steady-state digoxin plasma concentration and urinary excretion in patients with wide range of renal function. Ten patients (mean age 58 years) with creatinine clearances greater than 50 ml/min/1.73 m2 BSA (mean creatinine clearance 80 ml/min/1.73 m2 BSA) and nine patients mean age 61 years) with creatinine clearances less than 50 ml/min/1.73 m2 BSA (mean creatinine clearance 20 ml/min/1.73 m2 BSA) were given digoxin tablets orally at two or three different dose levels (dose range 0.0313--0.5 mg/day). After a dosing period equal to at least five half-lives, three to four consecutive daily digoxin plasma concentrations were determined. Plasma concentrations and urinary digoxin excretion were measured during one 24-hour dosing interval at each dose level. Digoxin plasma and urine concentrations were determined in triplicate using radioimmunoassay. Individual patient plots provided evidence of linearity for: digoxin 24-hour steady-state plasma concentration vs dose; digoxin 24-hour cumulative urinary excretion versus dose; and area under the digoxin plasma concentration-time curve during a 24-hour dosing interval vs dose. Absolute values for these various parameters indicated substantial interpatient variation probably due to patient differences in both digoxin absorption and digoxin total body clearance. These results indicate that there is a linear relationship between digoxin plasma concentration and dose in patients with normal and decreased renal function. This linearity is support for dose-independent pharmacokinetics of digoxin in man. We conclude from these data that a change in digoxin dose should result in a proportional change in digoxin plasma concentration over the dose range examined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of renal function on plasma digoxin levels in elderly ambulant patients in domiciliary practice.

An investigation into the relations between the daily dose of digoxin, drug regimen, serum digoxin concentration, and creatinine and digoxin clearance was carried out in a group of elderly ambulant patients in domiciliary practice. Moderate to severe impairment of renal function was found both in patients taking digoxin and in elderly control subjects. Plasma digoxin levels were not related to ...

متن کامل

مقایسه تجویز کم تر از 5 میلی گرم روزانه با 15 میلی گرم یک روز در میان اسیدفولیک در کاهش هیپرهموسیستئینمی بیماران همودیالیزی

Background and purpose: Hyperhomocysteinemia is common among patients with renal failure and the risk of cardiovascular diseases increases with hyperhomocysteinemia. The aim of this study was to compare the efficacy of two doses of folic acid (2 and 7.5 mg/day ) in decreasing plasma concentration of homocysteine in ËSRD patients receiving regular hemodialysis therapy. Materials and methods...

متن کامل

بررسی ارتباط لپتین با عوامل خطر بیماریهای عروق کرونر قلب در بیماران مبتلا به دیابت نوع II در مقایسه با افراد غیر دیابتی

Introduction & Objective: Leptin is considered to play an important role in the regulation of body weight and metabolism. Many studies have shown an association between BMI and leptin concentration. Our study compares the relationship between plasma leptin levels and risk factors for CHD in patients with type 2 diabetes and non-diabetic controls. Materials & Methods: A total of 88 patients w...

متن کامل

Measurement of plasma digoxin concentration by radioimmunoassay.

A rapid, sensitive, and precise method for measuring the plasma digoxin concentration has been developed with the radioimmunoassay technique. Seventy patients receiving digoxin were shown to have plasma digoxin concentrations between 0.4 and 5 ng./ml. Preliminary studies show that though there is a positive correlation between total daily dose and the plasma digoxin concentration, the relations...

متن کامل

The Relationship between the Plasma Level of Cyclosporine-A and Drug Dose in Patients of Kermanshah Kidney Transplantation Center

Background: Nowadays the main problem in transplantation is the complexity of host immune system protection against the immunological and destructive reactions of the transplanted organ. High serum level of the immunosuppressive drug may cause toxicity and low serum level leads to the rejection of the transplanted organ. Cyclosporine has been known as the most effective immunosuppressive drug. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 58 6  شماره 

صفحات  -

تاریخ انتشار 1978