Effect of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow measured by ultrasound dilution

نویسندگان

  • Hoon Suk Park
  • Seok Hui Kang
  • Byung Ha Chung
  • Bum Soon Choi
  • Cheol Whee Park
  • Chul Woo Yang
  • Yong-Soo Kim
چکیده

BACKGROUND Prospective access flow measurement is the preferred method for vascular access surveillance in hemodialysis (HD) patients. We studied the effect of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow measured by ultrasound dilution. METHODS Access flow was measured 30 minutes, 120 minutes, and 240 minutes after the start of HD by ultrasound dilution in 30 patients during 89 HD sessions and evaluated for variation. RESULTS The mean age of the 30 patients was 62±11 years: 19 were male. The accesses comprised 16 fistulae and 14 grafts. The mean access flow over all sessions decreased by 6.1% over time (1265±568 mL/min after 30 minutes, 1260±599 mL/min after 120 minutes, and 1197±576 mL/min after 240 minutes, P<0.01 by repeated measures ANOVA). In addition, a≥5% decrease in mean arterial pressure during HD significantly reduced access flow (P=0.014). However, no other variable (ultrafiltration volume, sex, age, presence of diabetes, type or location of access, body surface area, hemoglobin, serum albumin level) interacted significantly with the effect of time on access flow. Furthermore, mean arterial pressure did not correlate with ultrafiltration volume. CONCLUSION We conclude that the variation in access flow during HD is relatively small. Decreased blood pressure is a risk factor for variation in access flow measured by ultrasound dilution. In most patients whose blood pressures are stable during HD, the access flow can be measured at any time during the HD treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining when to measure vascular access flow …that may not be enough

Vascular access in hemodialysis patients is crucial. Vascular access monitoring to ensure access patency is important for patient survival, quality of life, and blood vessel care. The ultrasound dilution method for measuring access flow is a screening tool to assess access dysfunction. Park et al. [1] performed a single-center prospective study of the variation in access flow during hemodialysi...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Short and Long-Term Effects of the Angiotensin II Receptor Blocker Irbesartan on Intradialytic Central Hemodynamics: A Randomized Double-Blind Placebo-Controlled One-Year Intervention Trial (the SAFIR Study)

BACKGROUND AND AIM Little is known about the tolerability of antihypertensive drugs during hemodialysis treatment. The present study evaluated the use of the angiotensin II receptor blocker (ARB) irbesartan. DESIGN Randomized, double-blind, placebo-controlled, one-year intervention trial. SETTING AND PARTICIPANTS Eighty-two hemodialysis patients with urine output >300 mL/day and dialysis vi...

متن کامل

Comparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis

Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...

متن کامل

Intradialytic hypertension is a marker of volume excess.

BACKGROUND Intradialytic blood pressure (BP) profiles have been associated with all-cause mortality, but its pathophysiology remains unknown. We tested the hypothesis that intradialytic changes in BP reflect excess volume. METHODS The dry weight reduction in hypertensive haemodialysis patients (DRIP) trial probed dry weight in 100 prevalent haemodialysis patients; 50 patients who did not have...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2013