Simulated joint and muscle forces in reversed and anatomic shoulder prostheses.
نویسندگان
چکیده
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
منابع مشابه
Comparison of polyethylene wear in anatomical and reversed shoulder prostheses.
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movemen...
متن کاملPolyethylene Wear in Anatomic and Reversed Shoulder Prostheses
INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...
متن کاملLong-term Results, Functional Outcomes and Complications after Open Reduction and Internal Fixation of Neglected and Displaced Greater Tuberosity of Humerus Fractures
Background: Humerus fractures include 5% to 8% of total fractures. Non-union and delayed union of GT (GT) fractures is uncommon; however they present a challenge to the orthopedic surgeons. Significant controversy surrounds optimal treatment of neglected fractures. The purpose of this article was to perform a comparative study to evaluate the outcomes of open reduction and internal fixatio...
متن کاملGlenohumeral contact forces in reversed anatomy shoulder replacement.
A major requirement to design an implant is to develop our understanding of the applied internal forces during everyday activities. In the absence of any basic apparatus for measuring forces directly, it is essential to rely on modelling. The major aim of this study was therefore to understand the biomechanical function of subjects with the reversed anatomy Bayley-Walker prosthesis, using an in...
متن کاملDesign rationale for a posterior/superior offset reverse shoulder prosthesis.
INTRODUCTION A computer model quantified and compared muscle lengths and moment arms of two different reverse shoulder arthroplasty humeral tray designs during two different motions. METHODS The computer model simulated internal/ external rotation and abduction in the scapular plane for the normal shoulder, the 38 mm non-offset, and the 38 mm posterior-superior offset reverse shoulders. Muscl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 6 شماره
صفحات -
تاریخ انتشار 2008