Automated system for the measurement of airways resistance, lung volumes, and flow-volume loops.
نویسندگان
چکیده
Using a digital computer and body plethysmograph measurements of airways resistance, lung volumes, and flow-volume loops may be obtained from a single manoeuvre performed by the patient. All the measurements together with a display of the flow-volume loop are displayed within 10 seconds of the patient completing the manoeuvre. The system appears to offer considerable advantages in speed, objectivity, and reproducibility when compared with conventional methods.
منابع مشابه
Small airways: a time to revisit?
The branching network of airways in the lung poses a complex challenge to both physiologists and physicians. Measurements of lung function have been made for nearly 200 years. Davy (1800) and Hutchinson (1844) were amongst the first to recognise and measure lung volumes. Despite these early discoveries, progress in understanding pulmonary physiology was intermittent. Rohrer (1925) and Rahn (194...
متن کاملFurther observations on respiratory flow-volume loops: clinical evaluation of a new oral bronchodilator, CP-12,521-1.
PRESSUBE, VOLUME, AND FLOW DATA obtained during spirometry and plotted as pressure-volume or flow-volume loops have been used in the study of respiratory mechanics. Pressure-volume loops are used for the display of data generated in the measurement of static and dynamic compliance of the lungs and/or chest wall. 1-~ Flow-volume loops have been used for the quick pattern-recognition of various p...
متن کاملبررسی تغییرات حجمهای ریه پس از اصلاح زاویه اسکولیوز
Background and Aim: The present studies on kyphoscoliosis operation demonstrate different results on lung volume changes. Some observations show increased, some show decreased and other studies show no changes in the dynamic respiratory flows.In this study we evaluated lung volumes before and after surgery. We also evaluated the correlation of repiratory lung volume changes with mean of Cob...
متن کاملVariation in airways resistance when defined over different ranges of airflows.
In eight normal subjects airways resistance (Raw) was assessed over six ranges of airflow (about zero flow at both minimum and maximum lung volumes) using an automated whole body plethysmograph. The intervals of flow used were 21s-1 and 11s-1 spanning zero flow, and 11s-1 and 0.51s-1 measured up to and from zero flow. The wider intervals gave less variable results, the coefficients of variation...
متن کاملThe accuracy of FEF25-75/ FVC for primary classification of the pulmonary function test
Introduction: The forced expiratory flow at 25 and 75% of the pulmonary volume/forced vital capacity ratio (FEF25-75/FVC) as a spirometry parameter has been successful in the early diagnosis of chronic obstructive pulmonary disease (COPD) and the methacholine challenge test for assessing airway responsiveness.To determine the accuracy of FEF25-7...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 36 12 شماره
صفحات -
تاریخ انتشار 1981