Electrochemical evaluation of a protein-imprinted polymer receptor

نویسندگان

  • Najmeh Karimian
  • Ashutosh Tiwari
چکیده

The selective detection and quantification of macromolecular targets is a fundamental biological mechanism in nature. Molecularly imprinted polymers (MIPs) have been identified as one of the most promising synthetic alternatives to bioreceptors. However, expanding this methodology towards selective recognition of bulky templates such as proteins appears to be extremely challenging due to problems associated with removal of the template from the polymeric network. In this study, polymer imprinted with troponin T (TnT) was assessed using electrochemical methods and the influence of various extraction methods, including conventional immersion extraction, thermal annealing and ultrasonic-assisted extraction, on the binding characteristics of the troponin-to-imprinted polymer receptor was elucidated. Cyclic voltammetric deposition of o-phenylenediamine (o-PD) film in the presence of TnT as a template was performed in acetate buffer (0.5 M, pH 5.2) on a gold substrate. Solvent extraction of the target molecule was optimised and followed by subsequent washing with water. The electrochemistry of a ferro/ferricyanide probe was used to characterise the TnT MIP receptor film. The incubation of the TnT MIP receptor-modified electrode with respect to TnT concentration resulted in a suppression of the ferro/ferricyanide redox current. The dissociation constant (K D) was calculated using a two-site model of template affinity for the TnT MIP receptor. The synthetic TnT MIP receptor had high affinity for TnT with a K D , of 2.3 × 10-13 M.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

Fabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin

A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

The Electrochemical Sensor for Selective Solid Phase Extraction of Pseudoephedrine Hydrochloride in a Real Sample

In  the  current  study,  a  new  technique  was  developed  for  quantification  and  qualification  of pseudoephedrine hydrochloride (PSE) in a real sample, which was based on electrochemical sensors and  molecular  imprinted  polymer  (MIP).  The  carbon  paste  electrode  (CPE)  was  modified  and optimized by a different ratio of MIP. MIP/CPE was used as the extraction and working electrod...

متن کامل

Development of A New Electrochemical Sensor based on Zr-MOF/MIP for Sensitive Diclofenac Determination

In this study, a new molecularly imprinted polymer with nanoporous material of zirconium metal-organic frameworks (Zr-MOF/MIP) for diclofenac (DFC) measurement is presented. The Zr-MOF/MIP was prepared by electropolymerization method, the Zr-MOFs were used to increase electrode surface and the DFC and para- aminobenzoic acid (pABA) were used as template and functional monomer, respectively. Zr-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014