The Hydrogen Ion Concentration of the Blood in certain Pathological Conditions, as Determined by the Hydrogen Electrode and the Indirect Methods of Barcroft and Hasselbalch.

نویسندگان

  • T R Parsons
  • E P Poulton
چکیده

HASSELBALCH [1913] was the first to establish the conditions under which the hydrogen electrode can be used to measure accurately the reaction of the body fluids, and he constructed curves for the PH of blood under varying C02 tensions. More recently Peters [1914] has improved Hasselbalch's method by using completely reduced blood for the'determinations, and'Parsons [1917] has shown that by the CH of blood is meant the CH of the plasma it contains, i.e. the plasma obtained by centrifuging the blood without loss of CO2-which' may be called the "true plasma" [Joffe and Poulton, 1920]. When once.the hydrogen electrode apparatus has been set up the determinations do not occupy any great length of time; but as ordinarily arranged the apparatus itself tends to be somewhat complicated. A much simplified arrangement is, however, being designed byone of us (T. R. P.) especially for use with body fluids: it is soon to be placed on the market by the Cambridge and Paul Scientific Instrument Company. In this the manipulations are reduced to a minimum. Barcroft's method [Barcroft and Peters, 1914] was introduced beforethe hydrogen electrode method had been finally perfected. It consists in determining at any required CO2 pressure the percentage saturation with oxygen of the haemoglobin of the blood at a given oxygen pressure, and from this calculating the value of log K in Hill's equation. Barcroft and Peters [1914] showed for Barcroft's blood that log K was a linear function of yp, and Hasselbalch [1916] found that in the case of six normal people the same relationship exiisted between the two values. Barcroft's method was used by Lewis, Ryflel, Wolf, Cotton and Barcroft [1913] in cases of. cardio-renal disease, by Poulton and Ryffel [1913] in cases of uraemia, and by Poulton

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adsorption of Cr(III) and Mg(II) from Hydrogen Peroxide Aqueous Solution by Amberlite IR-120 Synthetic Resin

In concentration of hydrogen peroxide, first, the solution should be quite pure, and then, it concentrate with methods such as vacuum distillation and cooling crystallization, because impurities in the hydrogen peroxide solution in high concentrations are causing decomposition of this substance; that is very dangerous. The purpose of this article is separation of chromium and magne...

متن کامل

Electrochemical Sulfate Removal from Aqueous Solution Using Sandwich Panel Carbon Cloth Electrode by Steel Mesh: A laboratory study

Background and Objectives: Sulfate is one of the chemical pollutants in water that can cause adverse health effects such as digestive and blood problems at high concentrations in humans. Conversion of sulfate to substances such as hydrogen sulfide can corrode metal pipes. Therefore, the aim of this study was to investigate the effect of electrochemical sulfate removal using a sandwich panel car...

متن کامل

Biosynthesis of Silver Nanoparticles Using Leaves of Acacia Melanoxylon and their Application as Dopamine and Hydrogen Peroxide Sensors

In this work, we described a cost-effective and environmentally friendly technique for green synthesis of colloidal silver nanoparticles from aqueous extract of fresh leaves of Acacia melanoxylon and its application as a dopamine and hydrogen peroxide sensor. The prepared silver nanoparticles were characterized by UV-Visible absorption spectroscopy, X-ray diffraction (XRD), scanning electron mi...

متن کامل

The Effect of Hydrogen Content and Welding Conditions on the Hydrogen Induced Cracking of the API X70 Steel Weld

In this study, first,diffusible hydrogen of cellulosic electrode E8010-P1 and low hydrogen electrode E8018-G was measured by mercury displacement method according to ISO3690. Then,the effect of preheating and post-heating on the sensitivity to hydrogen inducedcold cracking in welding of 18mm API5L X70 steel with these electrodes was investigated according to ISO17642-2. The results of visual in...

متن کامل

Development of An Immobilized Enzyme Electrode for the Determination of Sulfite Ion

An enzyme electrode was developed using the enzyme sulfite oxidase (EC1.8.3.1) immobilized onto pig intestine. Hydrogen peroxide produced was monitored amperometrically. All experimental parameters such as pH, temperature, buffer constituent concentration, were thoroughly investigated and optimized when appropriate. The response to sulfite concentration was linear in the range 5.2´...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Biochemical journal

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2005