In vitro Wear Rate and Co Ion Release of Compositionally and Structurally Graded CoCrMo-Ti6Al4V Structures.

نویسندگان

  • Stanley Dittrick
  • Vamsi Krishna Balla
  • Susmita Bose
  • Amit Bandyopadhyay
چکیده

Novel, unitized structures with porous Ti6Al4V alloy on one side and compositionally graded, hard CoCrMo alloy surface on the other side have been fabricated using laser engineered net shaping (LENS™) process. Gradient structures with 50%, 70% and 86% CoCrMo alloy on the top surface showed high hardness in the range of 615 and 957 HV. The gradient structures were evaluated for their in vitro wear rate and Co release up to 3000 m of sliding distance. The wear rate of ultrahigh molecular weight polyethylene and 100% CoCrMo alloy substrates found to depend on the hardness and microstructural features of the counter surface rubbing against them. In general, the wear rate of both the substrates increased with a decrease in the CoCrMo alloy concentration on the top surface of gradient pins. However, the wear rate of gradient pins was lower than 100% CoCrMo alloy pins due to their high hardness. Lowest wear rate in the range of 5.07 to 7.99 × 10(-8) mm(3)/Nm was observed for gradient pins having 86% CoCrMo alloy on the top surface. The amount of Co released, in the range of 0.38 and 0.91 ppm, during in vitro wear testing of gradient structures was comparable to that of 100% CoCrMo alloy (0.25 and 0.77 ppm). Present unitized structures with open porosity on one side and hard, wear resistant surface on the other side can minimize the wear-induced osteolysis and aseptic loosening, and eliminate the need for multiple parts with different compositions for load-bearing implants such as total hip prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of compositionally and structurally graded Ti-TiO2 structures using laser engineered net shaping (LENS).

Novel structures with functional gradation in composition and structure were successfully made in Ti-TiO(2) combination using laser engineered net shaping. The addition of fully dense, compositionally graded TiO(2) ceramic on porous Ti significantly increased the surface wettability and hardness. The graded structures with varying concentrations of TiO(2) on the top surface were found to be non...

متن کامل

The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys.

The mechanical and electrochemical behavior of the surface oxides of CoCrMo and Ti6Al4V alloys during fracture and repassivation play an important role in the corrosion of the taper interfaces of modular hip implants. This behavior was investigated in one group of CoCrMo and Ti6Al4V alloy samples passivated with nitric acid and another group coated with a novel TiN/AlN coating. The effects of m...

متن کامل

Preparation and Mechanical Properties of Compositionally Graded Polyethylene/Clay Nanocomposites

This paper presents the preparation and mechanical properties of compatibilized compositionally graded Polyethylene/ low density polyethylene (LDPE)/ modified montmorillonite (MMT) nanocomposites prepared by solution and melt mixing techniques. Use of polyethylene glycol as compatibilizer improves compatibility of modified montmorillonite and low density polyethylene.  Comparisons between two t...

متن کامل

CoCrMo metal-on-metal hip replacements.

After the rapid growth in the use of CoCrMo metal-on-metal hip replacements since the second generation was introduced circa 1990, metal-on-metal hip replacements have experienced a sharp decline in the last two years due to biocompatibility issues related to wear and corrosion products. Despite some excellent clinical results, the release of wear and corrosion debris and the adverse response o...

متن کامل

Silicon nitride for total hip replacements

Pettersson, M. 2015. Silicon nitride for total hip replacements. Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 1242. 53 pp. Uppsala: Acta Universitatis Upsaliensis. ISBN 978-91-554-9211-3. For more than 50 years total hip replacements have been a common and successful procedure to increase patient mobility and quality of life. The 10-year im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Materials science & engineering. C, Materials for biological applications

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2011