Abnormal vasomotor function of porcine coronary arteries distal to sirolimus-eluting stents.
نویسندگان
چکیده
OBJECTIVES This study sought to determine vasomotor functional responses of conduit coronary artery distal to bare-metal stents (BMS), polymer-only stents (POLY), and sirolimus-eluting stents (SES) in a clinically relevant animal model. BACKGROUND Drug-eluting stents (DES) reduce in-stent restenosis, and also affect neointima formation and vascular remodeling in downstream coronary segments. Whether distal artery vasomotor function is also influenced by DES has not been determined. METHODS Pigs (n = 12) received coronary stent implants, and hearts were harvested at 1 month. Arterial segments >or=15 mm distal to stents were excised and studied in an organ-chamber apparatus. Endothelium-dependent and endothelium-independent relaxation and contraction to classical agonists were measured. RESULTS The SES showed increased lumen area and reduced neointima; abnormal vasomotor function of conduit arteries distal to SES also was observed. Contraction to endothelin-1 was significantly enhanced for SES compared with both BMS and POLY. Endothelium-dependent relaxation to a maximal dose of substance P was attenuated for SES compared with both BMS and POLY (46 +/- 6% vs. 71 +/- 3% and 78 +/- 3%, respectively, p < 0.001). Endothelium-independent relaxation to sodium nitroprusside was potentiated for SES, compared with BMS and POLY (100 +/- 5% vs. 69 +/- 7% and 77 +/- 5%, respectively, p = 0.02). CONCLUSIONS Stent-based local delivery of sirolimus profoundly inhibited neointima formation but caused vasomotor dysfunction in distal conduit vessel segments. These observations suggest that distal coronary vasospasm may be more readily evoked in the presence of DES and contribute to pathophysiological sequela.
منابع مشابه
Combined therapeutic strategy to improve vascular endothelial function after implantation of sirolimus-eluting stents.
oronary arteries are readily blocked by atherosclerotic plaques, eventually triggering cardiovascular events (ie, ischemic coronary heart disease and myocardial infarction) in patients. Stent implantation is one strategy often used to attenuate the progression of coronary artery atherosclerosis and decrease cardiovascular-related mortality. Stents significantly reduce the risk rate of restenosi...
متن کاملEvaluation of a tapered polymer-free sirolimus-eluting stent in porcine coronary arteries
Background: No stent is yet available for tapering coronary arteries. The purpose of the present study is to evaluate the applicability, efficacy and safety of a novel tapered, polymer-free sirolimus eluting stent (t-PFSES) specifically designed for tapering coronary arteries. Methods: 28 pigs underwent the placement of 56 oversized stents (control, n = 28, t-PFSES, n = 28), and quantitative co...
متن کاملInterference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.
BACKGROUND There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes. METHODS AND RESULTS Patients with paclit...
متن کاملNanoporous CREG-Eluting Stent Attenuates In-Stent Neointimal Formation in Porcine Coronary Arteries
BACKGROUND The goal of this study was to evaluate the efficacy of a nanoporous CREG-eluting stent (CREGES) in inhibiting neointimal formation in a porcine coronary model. METHODS In vitro proliferation assays were performed using isolated human endothelial and smooth muscle cells to investigate the cell-specific pharmacokinetic effects of CREG and sirolimus. We implanted CREGES, control sirol...
متن کاملSafety and Efficacy of New Sirolimus-eluting Stent Models in a Preclinical Study.
INTRODUCTION AND OBJECTIVES Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary art...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 1 3 شماره
صفحات -
تاریخ انتشار 2008