Design and Analysis of Artifact-resistive Finger Photoplethysmographic Sensors for Vital Sign Monitoring
نویسندگان
چکیده
A miniaturized, telemetric, photoplethysmograph sensor for long-term, continuous monitoring is presented in this thesis. The sensor, called a "ring sensor," is attached to a finger base for monitoring beat-to-beat pulsation, and the data is sent to a host computer via a RF transmitter. Two major design issues are addressed: one is to minimize motion artifact and the other is to minimize the consumption of battery power. An efficient double ring design is developed to lower the influence of external force, acceleration, and ambient light, and to hold the sensor gently and securely on the skin, so that the circulation at the finger may not be obstructed. To better understand the mechanism of motion artifact by external forces, a comprehensive mathematical model describing the finger photoplethysmography was developed and verified by finite element method, numerical simulation and experiments. Total power consumption is analyzed in relation to the characteristics of the individual components, sampling rate, and CPU clock speed. Optimal operating conditions are obtained for minimizing the power budget. A prototype ring sensor is designed and built based on the power budget analysis and the artifact-resistive attachment method. It is verified through experiments that the ring sensor is resistant to interfering forces and acceleration acting on the ring body. It is also shown that the device meets diverse and conflicting requirements, including compactness, motion artifact reduction, minimum loading effects, and low battery power consumption. Benchmarking tests with FDA-approved photoplethysmograph and EKG reveal that the ring sensor is comparable to those devices in detecting beat-to-beat pulsation despite disturbances. The long-term monitoring experiment shows that this device can effectively provide a considerable amount of artifact-free vital sign information in everyday life. Finally, guidelines for designing the ring sensor are proposed based on the analyses and the experiment results. Thesis Committee Members: Professor Harry H. Asada, Chairman Professor Roger D. Kamm Professor Roger G. Mark Dr. Boo-Ho Yang
منابع مشابه
Design and fabrication of a rapid conductometric pH sensor based on metal-oxide technology
A micro-fabricated metal-oxide based conductometric pH sensor is designed and fabricated in this manuscript. pH sensors have applications in various areas from farming to food processing, human health monitoring, industrial waste products investigation, etc. Accordingly, there is a relatively high demand for a reliable, rapid and precise pH sensor in the market. Relatively precise pH sensors ha...
متن کاملRespiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform
The photoplethysmographic waveform sits at the core of the most used, and arguably the most important, clinical monitor, the pulse oximeter. Interestingly, the pulse oximeter was discovered while examining an artifact during the development of a noninvasive cardiac output monitor. This article will explore the response of the pulse oximeter waveform to various modes of ventilation. Modern digit...
متن کاملPulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.
PURPOSE OF REVIEW This article reviews the development of novel reflectance pulse oximetry sensors for the esophagus and bowel, and presents some of the techniques used to analyze the waveforms acquired with such devices. RECENT FINDINGS There has been much research in recent years to expand the utility of pulse oximetry beyond the simple measurement of arterial oxygen saturation from the fin...
متن کاملImproving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information ...
متن کاملHigh-Resolution Time-Frequency Analysis Of Neurovascular Responses To Ischemic Challenges
DETECTION OF 900 ML BLOOD WITHDRAWAL BY AMPLITUDE MODULATION ANALYSIS OF THE PHOTOPLETHYSMOGRAPHIC WAVEFORM Christopher G. Scully, MS, Nandakumar Selvaraj, PhD, Frederick W. Romberg, MS, Richa Wardhan, MD, John Ryan, BA, John Florian, PhD, David G. Silverman, MD, Kirk H. Shelley, MD, PhD, and Ki H. Chon, PhD Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA De...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -