Determination of microvascular flow pattern formation in vivo.

نویسندگان

  • K Osterloh
  • P Gaehtgens
  • A R Pries
چکیده

Blood flow in microvessels differs significantly from that of red blood cells (RBC) flowing through long, straight glass tubes in vitro. The in vivo situation is characterized by the presence of plasma favoring aggregation, by the irregular geometry of vessel segments, and by frequent branching points. Here, a method is presented to characterize flow patterns in microvascular blood flow during intravital microscopy based on Fourier analysis of recorded light intensity patterns. The interpretation of the resulting power spectra in terms of pattern size distribution was validated by model experiments employing artificial textures and by reverse transformation of idealized spectra. The determined size of RBC flow patterns in microvessels ranged from approximately 8 microm in capillaries to approximately 14 microm in vessels of >30 microm. With increasing shear rate above approximately 100 s(-1) pattern size increased, possibly reflecting formation of short-lived flow clusters. Below approximately 100 s(-1) an increase of pattern size with decreasing shear rate was found in experiments using local occlusion and treatment with high-molecular-weight dextran, suggesting the formation of aggregates. The dynamic process of generation and destruction of RBC flow patterns could well contribute to flow resistance in vivo in peripheral vascular beds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AHEART April 47/4

Osterloh, Kurt, Peter Gaehtgens, and Axel R. Pries. Determination of microvascular flow pattern formation in vivo. Am J Physiol Heart Circ Physiol 278: H1142–H1152, 2000.—Blood flow in microvessels differs significantly from that of red blood cells (RBC) flowing through long, straight glass tubes in vitro. The in vivo situation is characterized by the presence of plasma favoring aggregation, by...

متن کامل

Analysis of Flow Pattern with Low Reynolds Number around Different Shapes of Bridge Piers, and Determination of Hydrodynamic Forces, using Open Foam Software

In many cases, a set of obstacles, such as bridge piers and abutments, are located in the river waterway. Bridge piers disrupt river’s normal flow, and the created turbulence and disturbance causes diversion of flow lines and creates rotational flow. Geometric shape and position of the piers with respect to flow direction and also number of piers and their spacing are effective on changing the ...

متن کامل

Morphogenetic Mechanisms of Endothelial Cells During Lumen Formation in Sprouting Angiogenesis

Different mechanisms such as cell migration, proliferation, branching, anastomosis, and lumen formation occur during the angiogenesis process. Lumen formation is one of the critical mechanisms which is not only necessary for the functional plexus but also for continuing of angiogenesis process. Although multiple studies investigated this mechanism during the angiogenesis process in both in vivo...

متن کامل

The Indication of Two-Phase Flow Pattern and Slug Characteristics in a Pipeline Using CFD Method

Multiphase flows are commonly encountered in oil and gas industries. The transport of multiphase flow causes the formation of slug, the increase of pressure drop and the possibility of phase changes therefore, a set of simulation runs was performed to predict flow regimes in a horizontal pipeline, and the results were compared with the Baker chart. The effects of small downward inclinations of ...

متن کامل

Investigating the effect of Inlet and Outlet location on Flow field and Sedimentation pattern of a rectangular settling basin using CCHE2D

Water obtained from any source may contain impurities induced by erosion, dissolved minerals, dissolved gases and material produced from organic matter decomposing. If the amount of these substances exceed a certain limit, not only the water would not be potable, but the water containing the material will not be suitable to be used in most applications, or at least before treatment cannot be ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 278 4  شماره 

صفحات  -

تاریخ انتشار 2000