Reconstruction of myocardial tissue motion and strain fields from displacement-encoded MR imaging.

نویسندگان

  • Yi Liu
  • Han Wen
  • Robert C Gorman
  • James J Pilla
  • Joseph H Gorman
  • Gerald Buckberg
  • Shawn D Teague
  • Ghassan S Kassab
چکیده

A quantitative analysis of myocardial mechanics is fundamental to understanding cardiac function, diagnosis of heart disease, and assessment of therapeutic intervention. Displacement encoding with stimulated-echo (DENSE) magnetic resonance imaging (MRI) technique was developed to track the three-dimensional (3D) displacement vector of discrete material grid points in the myocardial tissue. Despite the wealth of information gained from DENSE images, the current software only provides two-dimensional in-plane deformation. The objective of this study is to introduce a postprocessing method to reconstruct and visualize continuous dynamic 3D displacement and strain fields in the ventricular wall from DENSE data. An anatomically accurate hexagonal finite-element model of the left ventricle (LV) is reconstructed by fitting a prolate spheroidal primitive to contour points of the epi- and endocardial surfaces. The continuous displacement field in the model is described mathematically based on the discrete DENSE vectors using a minimization method with smoothness regularization. Based on the displacement, heart motion and myocardial stretch (or strain) are analyzed. Illustratory computations were conducted with DENSE data of three infarcted and one normal sheep ventricles. The full 3D results show stronger overall axial shortening, wall thickening, and twisting of the normal LV compared with the infarcted hearts. Local myocardial stretches show a dyskinetic LV in the apical region, dilation of apex in systole, and a compensatory increase in strain in the healthy basal region as a compensatory mechanism. We conclude that the proposed postprocessing method significantly extends the utility of DENSE MRI, which may provide a patient-specific 3D model of cardiac mechanics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional myocardial function: advances in MR imaging and analysis.

Cardiovascular magnetic resonance (MR) imaging can provide three-dimensional analysis of global and regional cardiac function with great accuracy and reproducibility. Quantitative assessment of regional function with cardiac MR imaging previously was limited by long acquisition times and time-consuming analysis. The use of steady-state free precession cine MR imaging substantially improves asse...

متن کامل

Latest pulse sequence for displacement-encoded MR imaging incorporates essential technical improvements for multiphase measurement of intramyocardial strain.

The article by Kim et (1) presents a significant step forward in the evolution of magnetic resonance (MR) imaging techniques to measure two-dimensional intramyocardial displacement and strain. The pulse sequence described in reference 1 is the latest in a set of sequences that have built on an innovative technique called displacement encoding with stimulated echoes (DENSE) (2). The DENSE pulse ...

متن کامل

Myocardial Strain Imaging with Tagged MRI

A 4-D B-spline model has been created to accurately capture the dynamic motion of the heart from tagged magnetic resonance imaging (MRI) enabling displacement field reconstruction of myocardial deformation. The 4-D model is allowed to deform based on the location of the tag lines for all frames within the constraints of the model’s spatiotemporal internal energy. From a displacement field, the ...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

MRI of Longitudinal Myocardial Strain using Multislice Cine DENSE with Through-plane Displacement Encoding

Introduction Cine DENSE (Displacement Encoding with Stimulated Echoes) is a quantitative MRI method for imaging myocardial displacement and strain. Typically, cine DENSE images of the heart are acquired in a short-axis plane, and the in-plane circumferential and radial displacements and strains are measured. However, quantitative imaging of longitudinal myocardial motion is also important, as i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 297 3  شماره 

صفحات  -

تاریخ انتشار 2009