Study of human precorneal tear film thickness and structure using laser interferometry.

نویسندگان

  • J I Prydal
  • P Artal
  • H Woon
  • F W Campbell
چکیده

The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45 microns, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46 microns. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min exposure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11 microns, and thickness slowly increased to reach its original value over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of precorneal tear film thickness and structure by interferometry and confocal microscopy.

Past measurements of precorneal tear film thickness in rabbits and humans gave values of 4-7 microns. These have been the accepted values. However, measurements presented in this report are much higher. Earlier techniques may have changed film thickness or not have fully included the layer containing mucus. Little is known about the mucus component. Thickness was measured in freshly killed anim...

متن کامل

A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.

PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Measuring of corneal thickness of contact lens wearers with keratoconus and keratoplasty by means of optical coherence tomography (OCT).

To measure the corneal thickness and the depth of the precorneal tear film of contact lens wearers with keratoconus or keratoplasty and to reconfirm the identification and classification of the keratoconus with optical coherence tomography (OCT). The cornea and precorneal tear film of 123 eyes with keratoconus, of 39 eyes after keratoplasty and 8 eyes after LASIK were examined with an OCT (Zeis...

متن کامل

Tear film interferometry and corneal surface roughness.

PURPOSE Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre-contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 1992