Strategies for measurement of atmospheric column means of carbon dioxide from aircraft using discrete sampling

نویسندگان

  • P. S. Bakwin
  • P. P. Tans
  • B. B. Stephens
  • S. C. Wofsy
  • C. Gerbig
  • A. Grainger
چکیده

[1] Automated flask sampling aboard small charter aircraft has been proposed as a lowcost, reliable method to greatly increase the density of measurements of CO2 mixing ratios in continental regions in order to provide data for assessment of global and regional CO2 budgets. We use data from the CO2 Budget and Rectification-Airborne 2000 campaign over North America to study the feasibility of using discrete (flask) sampling to determine column mean CO2 in the lowest 4 km of the atmosphere. To simulate flask sampling, data were selected from profiles of CO2 measured continuously with an onboard (in situ) analyzer. We find that midday column means can be determined without bias relative to true column means measured by the in situ analyzer to within 0.15 and better than 0.10 ppm by using 10 and 20 instantaneously collected flask samples, respectively. More precise results can be obtained by using a flask sampling strategy that linearly integrates over portions of the air column. Using less than 8–10 flasks can lead to significant sampling bias for some common profile shapes. Sampling prior to the breakup of the nocturnal stable layer will generally lead to large sampling bias because of the inability of aircraft to probe large CO2 gradients that often exist very close to the ground at night and during the early morning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon dioxide column abundances at the Wisconsin Tall Tower site

[1] We have developed an automated observatory for measuring atmospheric column abundances of CO2 and O2 using near-infrared spectra of the Sun obtained with a high spectral resolution Fourier Transform Spectrometer (FTS). This is the first dedicated laboratory in a new network of ground-based observatories named the Total Carbon Column Observing Network. This network will be used for carbon cy...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

Preparation of Graphene-amine Nanofluid for Absorption of Carbon Dioxide (CO2) and Hydrogen Sulfide (H2S) from a Natural Gas Stream in a Wetted Wall Column

    In this study, it was shown that how CO2 and H2S were removed from a natural gas stream, using a nanofluid containing nanoporous graphene in Diehanolamine (DEA). Before running the experiments, the appropriate values were chosen for the nanosheet dosage and the liquid and gas flow rates in the absorption experiments, which were performed in a laboratory scale wetted wall column. In the expe...

متن کامل

Airborne measurements of CO2 column absorption and range using a pulsed direct-detection integrated path differential absorption lidar.

We report on airborne CO(2) column absorption measurements made in 2009 with a pulsed direct-detection lidar operating at 1572.33 nm and utilizing the integrated path differential absorption technique. We demonstrated these at different altitudes from an aircraft in July and August in flights over four locations in the central and eastern United States. The results show clear CO(2) line shape a...

متن کامل

Precision Column Coe Measurement from Space using Broad Band LIDAR

In order to better understand the budget of carbon dioxide in the Earth's atmosphere it is necessary to develop a global high precision understanding of the carbon dioxide column. To uncover the `missing sink" that is responsible for the large discrepancies in the budget as we presently understand it, calculation has indicated that measurement accuracy of 1 ppm is necessary. Because typical col...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003