Evaluation of Optical Low Coherence Reflectometry Parameters in Patients with Exfoliation Syndrome
نویسندگان
چکیده
Purpose. To evaluate optical low coherence reflectometry (OLCR) parameters in patients with exfoliation syndrome (EXS) undergoing cataract surgery. Methods. Forty-seven eyes of 47 patients with EXS (Group 1), and 55 eyes of 55 healthy subjects (Group 2) were included in the study. Anterior chamber depth (ACD), lens thickness (LT), axial length (AL), central corneal thickness (CCT), horizontal corneal length (HCL), and pupil diameter (PD) parameters were measured by OLCR (Lenstar LS 900, Haag-Streit) and compared between groups. Shapiro-Wilk test and Mann Whitney U tests were used for statistical analyses. Results. The mean ACD, HCL, and PD values were significantly lower in EXS group than in healthy subjects (P = 0.01, P = 0.04, and P < 0.001, resp.). The mean LT was significantly higher in EXS group than in healthy subjects (P = 0.007). There was no significant difference between groups in means of AXL and CCT. Conclusions. According to OLCR measures, eyes with EXS have shallower ACD, smaller PD, thicker LT, shorter HCL, and no significantly different CCT levels.
منابع مشابه
Evaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion
Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...
متن کاملPolarization-Independent Optical Low-Coherence Reflectometry with a Non-Birefringent Arrayed- Waveguide Grating
The polarization dependency of an arrayed-waveguide grating (AWG) in an optical low-coherence reflectometry system is investigated. For mixed polarization, signal fading is observed at specific depths. This fading is eliminated by using a nonbirefringent AWG. Keywords-arrayed waveguide grating; Non-Birefringent waveguides; Optical Low-coherence Reflectometry
متن کاملOptical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients
Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients. Objectives: T...
متن کاملCentral corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.
BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...
متن کاملPhase Noise Considerations in Coherent Optical FMCW Reflectometry
phase noise, coherent reflectometry, FMCW, Rayleigh backscattering, fiberoptic interferometry An analysis of coherent optical FMCW is presented. It shows the limitations imposed on measurements of discrete reflections and of Rayleigh backscattering due to phase noise originating in the finite coherence length of the optical source. The dependence of the range for accurate measurements on partic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015