Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries.

نویسندگان

  • J J Wentzel
  • R Krams
  • J C Schuurbiers
  • J A Oomen
  • J Kloet
  • W J van Der Giessen
  • P W Serruys
  • C J Slager
چکیده

BACKGROUND In-stent restenosis by excessive intimal hyperplasia reduces the long-term clinical efficacy of coronary stents. Because shear stress (SS) is related to plaque growth in atherosclerosis, we investigated whether variations in SS distribution are related to variations in neointima formation. METHODS AND RESULTS In 14 patients, at 6-month follow-up after coronary Wallstent implantation, 3D stent and vessel reconstruction was performed with a combined angiographic and intravascular ultrasound technique (ANGUS). The bare stent reconstruction was used to calculate in-stent SS at implantation, applying computational fluid dynamics. The flow was selected to deliver an average SS of 1.5 N/m(2). SS and neointimal thickness (Th) values were obtained with a resolution of 90 degrees in the circumferential and 2.5 mm in the longitudinal direction. For each vessel, the relationship between Th and SS was obtained by linear regression analysis. Averaging the individual slopes and intercepts of the regression lines summarized the overall relationship. Average Th was 0.44+/-0.20 mm. Th was inversely related to SS: Th=(0.59+/-0.24)-(0.08+/-0.10)xSS (mm) (P<0.05). CONCLUSIONS These data show for the first time in vivo that the Th variations in Wallstents at 6-month follow-up are inversely related to the relative SS distribution. These findings support a hemodynamic mechanism underlying in-stent neointimal hyperplasia formation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics].

INTRODUCTION AND OBJECTIVES Local factors may influence neointimal proliferation following conventional stent implantation. In this study, the relationship between wall shear stress and luminal loss after coronary stenting was assessed using a combination of angiography, intravascular ultrasound, and computational fluid dynamics. PATIENTS AND METHOD Seven patients with de novo right coronary ...

متن کامل

The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans.

OBJECTIVES We aimed to explore the relationship of neointimal thickness (NT) to shear stress (SS) after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) compared with bare-metal stents (BMS). We then tested the hypothesis that drug elution attenuates the SS effect. BACKGROUND Neointimal thickness after BMS implantation has been associated with SS; pertinent d...

متن کامل

Helical Velocity Patterns in a Human Coronary Artery A Three-Dimensional Computational Fluid Dynamic Reconstruction Showing the Relation With Local Wall Thickness

A74-year-old man was referred to our catheterization laboratory for elective angioplasty of the right coronary artery (RCA). One year earlier, he had suffered an acute inferior myocardial infarction, which was successfully treated with intravenous streptokinase. Only minor creatinine phosphokinase elevations were found. Since that time, however, the patient had frequently experienced exertional...

متن کامل

Antegrade iliac artery stent implantation for the temporal and spatial examination of stent-induced neointimal hyperplasia and alterations in regional fluid dynamics.

INTRODUCTION Neointimal hyperplasia remains an important problem after stent implantation. Previous investigations examining vascular responses to stent implantation and effects of drugs have used a retrograde deployment approach that may inadvertently alter the local fluid dynamics surrounding the stent. We present a model of antegrade iliac artery stent implantation that facilitates the analy...

متن کامل

Helical velocity patterns in a human coronary artery: a three-dimensional computational fluid dynamic reconstruction showing the relation with local wall thickness.

A74-year-old man was referred to our catheterization laboratory for elective angioplasty of the right coronary artery (RCA). One year earlier, he had suffered an acute inferior myocardial infarction, which was successfully treated with intravenous streptokinase. Only minor creatinine phosphokinase elevations were found. Since that time, however, the patient had frequently experienced exertional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 103 13  شماره 

صفحات  -

تاریخ انتشار 2001