Coherent Imaging without Phases
نویسندگان
چکیده
Abstract. In this paper we consider narrow band, active array imaging of weak localized scatterers when only the intensities are recorded at an array with N transducers. We consider that the medium is homogeneous and, hence, wave propagation is fully coherent. This work is an extension of our previous paper [21] where we showed that using linear combinations of intensityonly measurements, obtained from N2 illuminations, imaging of localized scatterers can be carried out efficiently using imaging methods based on the singular value decomposition of the time-reversal matrix. Here we show the same strategy can be accomplished with only 3N−2 illuminations, therefore reducing enormously the data acquisition process. Furthermore, we show that in the paraxial regime one can form the images by using six illuminations only. In particular, this paraxial regime includes Fresnel and Fraunhofer diffraction. The key point of this work is that if one controls the illuminations, imaging with intensity-only can be easily reduced to a imaging with phases and, therefore, one can apply standard imaging techniques. Detailed numerical simulations illustrate the performance of the proposed imaging strategy with and without data noise.
منابع مشابه
Synthetic-aperture direct-detection coherent imaging
This paper describes an approach to coherent aperture synthesis and fine-resolution image reconstruction employing phase retrieval from intensity measurements. A Gerchberg-Saxton algorithm is used on a pair of intensity measurements to obtain the fields for each telescope at each position of the telescopes without a reference beam. These are combined into a larger synthetic aperture, and a cros...
متن کاملThree-dimensional coherent x-ray diffraction imaging of molten iron in mantle olivine at nanoscale resolution.
We report quantitative 3D coherent x-ray diffraction imaging of a molten Fe-rich alloy and crystalline olivine sample, synthesized at 6 GPa and 1800 °C, with nanoscale resolution. The 3D mass density map is determined and the 3D distribution of the Fe-rich and Fe-S phases in the olivine-Fe-S sample is observed. Our results indicate that the Fe-rich melt exhibits varied 3D shapes and sizes in th...
متن کاملResting Enhances Learning of Coherent Signals on Cellular Level in STDP Simulations
Spike-timing dependent synaptic plasticity (STDP) is a mechanism occurring in many areas of our brain. If synapses experience a coherent input signal, they may strengthen the corresponding synapses. By simulations we demonstrate that an input signal is learned best if it is not presented permanently, but rather if the presentation is intercepted by resting phases, i.e., by phases without any co...
متن کاملSpeckle-free laser imaging using random laser illumination.
Many imaging applications require increasingly bright illumination sources, motivating the replacement of conventional thermal light sources with bright light-emitting diodes, superluminescent diodes and lasers. Despite their brightness, lasers and superluminescent diodes are poorly suited for fullfield imaging applications because their high spatial coherence leads to coherent artefacts such a...
متن کاملMicro-beam Laue alignment of multi-reflection Bragg coherent diffraction imaging measurements.
Multi-reflection Bragg coherent diffraction imaging has the potential to allow three-dimensional (3D) resolved measurements of the full lattice strain tensor in specific micro-crystals. Until now such measurements were hampered by the need for laborious, time-intensive alignment procedures. Here a different approach is demonstrated, using micro-beam Laue X-ray diffraction to first determine the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- SIAM J. Imaging Sciences
دوره 9 شماره
صفحات -
تاریخ انتشار 2016