Pulse Wave Velocity and Cardiac Output vs. Heart Rate in Patients with an Implanted Pacemaker Based on Electric Impedance Method Measurement
نویسندگان
چکیده
The methods and device for estimation of cardiac output and measurement of pulse wave velocity simultaneously is presented here. The beat-to-beat cardiac output as well as pulse wave velocity measurement is based on application of electrical impedance method on the thorax and calf. The results are demonstrated in a study of 24 subjects. The dependence of pulse wave velocity and cardiac output on heart rate during rest in patients with an implanted pacemaker was evaluated. The heart rate was changed by pacemaker programming while neither exercise nor drugs were applied. The most important result is that the pulse wave velocity, cardiac output and blood pressure do not depend significantly on heart rate, while the stroke volume is reciprocal proportionally to the heart rate.
منابع مشابه
A System for Multi-Modal Assessment of Cardiovascular Parameters - Design and Measurements
This research introduces a novel multi-modal vital parameter measurement system and with some measurements taken. The system is able to accurately and simultaneously measure a single channel Electrocardiogram (ECG), four Photoplethysmograms (PPG), the pressure in both ears, as well as the broadband, time resolved thorax bioimpedance (ICG). The designed measurement system is based on a System on...
متن کاملAcute effects of 17b-estradiol on ventricular and vascular hemodynamics in postmenopausal women
Hayward, Christopher S., Wally V. Kalnins, and Raymond P. Kelly. Acute effects of 17b-estradiol on ventricular and vascular hemodynamics in postmenopausal women. Am J Physiol Heart Circ Physiol 279: H2277–H2284, 2000.—Because premenopausal women have lower cardiovascular morbidity than postmenopausal women, it has been proposed that estrogen may have a protective role. Estrogen is involved in s...
متن کاملPulse rate variability is not a surrogate for heart rate variability.
To investigate the differences between heart rate (HR) variability and pulse rate (PR) variability, short-term variability of finger pulse wave and ECG signals were studied in 10 children with a fixed ventricular pacemaker rhythm (80 beats/min). Ten healthy children in sinus rhythm served as a reference population. Distal PR and HR were measured continuously using a Finapres device and an ECG r...
متن کاملAcute effects of 17beta-estradiol on ventricular and vascular hemodynamics in postmenopausal women.
Because premenopausal women have lower cardiovascular morbidity than postmenopausal women, it has been proposed that estrogen may have a protective role. Estrogen is involved in smooth muscle relaxation both through its specific receptor as well as through calcium channel blockade. This study examined the acute effect of estradiol on invasive cardiovascular hemodynamics in 18 postmenopausal wom...
متن کاملEmergency Management of Pacemaker Failure
The purpose of this report is to describe the more common problems encountered with permanent pacemakers and their management. One of the serious recurring problems is loss of output from the pacemaker. As a result, no pacemaker impulse whatsoever is seen on the electrocardiogram and the heart rate appears slower than the fixed rate of the pacemaker. In such a situation, if a patient is pacemak...
متن کامل