Solid phase extraction and high performance liquid chromatography for the determination of azithromycin in human plasma.

نویسندگان

  • Sukanya Supattanapong
  • Julraht Konsil
چکیده

An effective, selective and sensitive method for the determination of azithromycin in plasma using high performance liquid chromatography-electrochemical detection (HPLC-ECD) extracted by solid phase extraction was developed and validated. Clarithromycin was used as an internal standard. Azithromycin was extracted from 1 ml of plasma using an Oasis HLB solid-phase extraction cartridge and the elution was evaporated to dryness, dissolved in 100 microl mobile phase and 40 microl auto-injected into an HPLC system with a 200 microl loop. The mobile phase was acetonitrile, methanol, phosphate buffer, 0.05M, pH 6.0 (20:20:60, v/v/v) with a flow rate of 1.0 ml/minute. The lower limit of quantitation (LLOQ) was 10 ng/ml without interfering peaks. The calibration curve was linear (r2 = 0.9998) over a concentration range 10 to 400 ng/ml. The accuracy and precision were acceptable. The mean recoveries at 30, 100 and 200 ng/ml were 85.3 +/- 5.5%, 80.1 +/- 6.8% and 82.9 +/- 2.5%, respectively. Azithromycin was stable in plasma for at least 6 hours at room temperature and 6 months storage at -80 degrees C. The post-preparation stability of spiked samples was more than 24 hours after preparation. The cartridge can be used two times providing a deviation of less than 4%. This method has adequate sensitivity, specificity, accuracy and precision to measure azithromycin in human plasma and is free from interference from the plasma matrix. The validated method was to quantify azithromycin plasma concentrations in five healthy Thai volunteers after the administration of 500 mg azithromycin capsules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Development of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples

A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Southeast Asian journal of tropical medicine and public health

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 2008