Tx/Rx Head Coil Induces Less RF Transmit-Related Heating than Body Coil in Conductive Metallic Objects Outside the Active Area of the Head Coil

نویسندگان

  • Zoltan Nagy
  • Aaron Oliver-Taylor
  • Andre Kuehne
  • Sigrun Goluch
  • Nikolaus Weiskopf
چکیده

The transmit-receive (Tx/Rx) birdcage head coil is often used for excitation instead of the body coil because of the presumably lower risk of heating in and around conductive implants. However, this common practice has not been systematically tested. To investigate whether the Tx/Rx birdcage head coil produces less heating than the body coil when scanning individuals with implants, we used a 3T clinical scanner and made temperature measurements around a straight 15 cm conductor using either the Tx/Rx body or the head coil for excitation. Additionally, the transmitted fields of a Tx/Rx head coil were measured both in air and in gel using a resonant and a non-resonant B field probes as well as a non-resonant E field probe. Simulations using a finite-difference time domain solver were compared with the experimental findings. When the body coil was used for excitation, we observed heating around the 15 cm wire at various anatomical locations (both within and outside of the active volume of the head coil). Outside its active area, no such heating was observed while using the Tx/Rx head coil for excitation. The E and B fields of the Tx/Rx birdcage head coil extended well-beyond the physical dimensions of the coil. In air, the fields were monotonically decreasing, while in gel they were more complex with local maxima at the end of the ASTM phantom. These experimental findings were line with the simulations. While caution must always be exercised when scanning individuals with metallic implants, these findings support the use of the Tx/Rx birdcage head coil in place of the body coil at 3T in order to reduce the risk of heating in and around conductive implants that are remote from the head coil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Implementation of a Novel 8-Ch Phase-Array Transmit/Receive Head Coil with RF Interface for Parallel Transmission on 3T

INTRODUCTION High and/or ultra-high field (UHF) whole-body MR spectrometer emerges as a cutting-edge new millennium technology [1-2]. With significantly higher signal to noise ratio (SNR) and higher resolution, it obtains increased abilities in detecting human microscopic structures comparable with conventional histology, which were previously unseen in lower field. It also enables the observat...

متن کامل

1H/23Na dual-tuned RF Unicoil for human body MR imaging at 3T

[Introduction] When a radio frequency (RF) coil is designed and built for MR imaging, its performance is judged on the basis of achieving uniform imaging B1field and high signal-to-noise ratio (SNR). However, there is an intrinsic trade-off between B1-field uniformity and high SNR in the configuration of RF coil; a large RF coil tends to generate a more uniform B1-field but lower SNR, because i...

متن کامل

Improved B1+ field using a 16-channel Transmit Head Array and an 8-channel pTx System at 7T

INTRODUCTION At 7T, transmit coil arrays using parallel transmit (pTx) [1] systems enable techniques to substantially improve B1 transmit fields. Receive coil arrays offer enhanced sensitivity and parallel imaging performance. However, significant challenges in ultra high field systems are still remaining for the design and implementation of RFcoils for dedicated transmit channels and their int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017